A watch stop or hacking mechanism moves a stop lever into contact with the balance when the stem enters the hand-setting position, immobilizing the oscillator so the hands can be synchronized. This calculator is a timing and entered-value calculation only.
Watch Stop Interactive Calculator
Enter beat rate, displayed amplitude, two force references and a restart-count reference. Outputs are conversions and entered-value differences—not stopping force, restart performance, damage risk or service limits.
Equation Used
- VPH counts half-oscillations and is divided by 7200 for full oscillations per second.
- Amplitude is entered for visual context and does not alter the timing conversion.
- Restart count is an entered reference multiplied by ideal oscillation period; it is not a restart prediction.
- Force references are entered independently and only their ordered difference is reported.
- Lever geometry, stem/cam travel, contact location, friction, spring stiffness, balance inertia, escapement torque, rebound, wear, damage, tolerances and movement-specific service limits are omitted.
Stem-Actuated Balance Stop
U.S. Patent 3,765,164 describes a hand-setting stem position causing a spring-lever stop portion to halt the balance wheel, a feature also called hacking. EP 4,296,793 describes a user-controlled stop lever moving between released and supporting/contact positions.
What This Calculator Represents
The tool converts VPH to full-oscillation frequency and period, multiplies period by an entered count, and subtracts two entered force references. It does not model the stop event.
Timing and Entered-Value calculation
T=1/f
count-duration=N T
force-reference span=max(F1,F2)−min(F1,F2)
Amplitude is displayed but does not enter these conversions.
Worked Arithmetic Example
At 28,800 vph, full-oscillation frequency is 4 Hz and period is 0.250 s. An entered count of two corresponds to a 0.500 s timing reference. Entered force references 0.5 and 2.0 mN have a span of 1.5 mN; that span is not an acceptable-force specification.
Assumptions and Limits
- Calculated: beat-rate conversions, count-times-period and an entered-force difference.
- Illustrated: generic balance wheel, pivoted stop lever and released/contact states.
- Not calculated: actual stopping or restart time, force, contact stress, friction, rebound, rate effects, damage, reliability or service procedure.
Frequently Asked Questions
Does the calculator predict how fast a watch restarts?
No; it only multiplies an entered count by ideal period.
Is the force span a safe working window?
No; both endpoints are user-entered references.
Does amplitude affect the outputs?
No; it is visual context only.
Does the animation prove contact geometry?
No; it is a generic topology cue.
Can this diagnose a movement?
No.
Should it guide watch service or modification?
No; use movement documentation and qualified watchmaking practice.
References
Building or designing a mechanism like this?
Explore the precision-engineered motion control hardware used by mechanical engineers, makers, and product designers.