Alpha Stirling Engine: Animation and Carnot Calculator | FIRGELLI

← Back to Engineering Library

An alpha Stirling engine has two sealed power pistons in separate hot and cold cylinders, connected by a working-gas path and a phased drive. The animation shows their relative motion. Change the hot and cold temperatures to compare the ideal Carnot efficiency ceiling, and change crank phase to see the piston timing. Engine power is not calculated.

Stirling Engine Alpha Interactive Calculator

Vary hot- and cold-space temperatures and crank phase. The calculator reports absolute temperatures, the ideal Carnot efficiency ceiling and deviation from nominal 90° phase; it does not predict engine power.

0°

Hot Abs.
--
Cold Abs.
--
Carnot Limit
--
Phase Error
--

Equation Used

T_hot_K = T_hot_C + 273.15; T_cold_K = T_cold_C + 273.15; eta_C = (1 - T_cold_K / T_hot_K) * 100; phase_error = |phase - 90|
Carnot efficiency is a thermodynamic upper bound, not expected shaft efficiency. Complete Schmidt analysis also needs swept-volume ratio, clearance/dead volumes, regenerator and heat-exchanger data.
  • Temperatures are converted to kelvin before the Carnot calculation.
  • Two sealed power pistons occupy separate expansion and compression cylinders.
  • The heater, regenerator and cooler are schematic.
  • No indicated work, brake power, pressure drop, leakage or mechanical loss is inferred.

Separate hot and cold power pistons are linked by the gas path and a shared phased crankshaft.

Supplementary Stirling-engine video
Video: ​​MEchanical Principle - Stirling Motor Power Generation #engine #mechanism #mechanical by Craft Mechanics on YouTube. Used here to complement the diagram below.
Same mechanism and inputs as the interactive calculator.

How the alpha arrangement works

The two cylinders share a sealed gas charge. One space receives heat and the other rejects it. The phased piston movements change the volumes of those spaces and move gas through the connecting heater, regenerator and cooler passages.

The regenerator stores heat as gas travels toward the cold space and returns heat during flow toward the hot space. Its real performance depends on heat transfer and flow resistance; the animation shows its place in the gas path without calculating those effects.

Reading the animation

  • Hot power piston: changes the expansion-space volume.
  • Cold power piston: changes the compression-space volume.
  • Gas path: connects the two spaces through the heat-exchange components.
  • Common shaft: couples the piston motions at the selected phase angle.
  • Crossheads and connecting rods: connect axial piston stems to the external cranks.

The 90° phase is the calculator’s reference setting. Deviation from that reference is reported in degrees; it is not a universal manufacturing tolerance or a percentage loss of power.

What this model helps explain

The alpha configuration separates expansion and compression into two cylinders. It is a useful example for studying how crank phase changes the relationship between two piston motions, and how hot and cold temperatures set a thermodynamic efficiency ceiling.

An externally heated engine may receive heat from different sources, but the heat source alone does not establish its layout or performance. This calculator does not identify commercial engine configurations, rate a generator, or select a working gas and charge pressure.

Temperature conversion and efficiency ceiling

Th = Th,C + 273.15 and Tc = Tc,C + 273.15 convert the entered Celsius temperatures to kelvin. For a heat engine operating between hot and cold reservoirs with Th greater than Tc and both above absolute zero, the Carnot ceiling is ηC = (1 − Tc/Th) × 100%.

The phase output is |φ − 90°|. It measures departure from the reference phase only and does not enter the Carnot equation.

The display limits the efficiency value to 0–100%. A cold temperature at or above the hot temperature does not describe heat-engine operation in the stated direction. The displayed bound is not a prediction of shaft efficiency, power or starting behavior.

Worked example: temperature ceiling and phase

Use an illustrative hot temperature of 650°C, cold temperature of 50°C and phase angle of 90°.

  1. Convert temperatures: Th = 923.15 K and Tc = 323.15 K.
  2. Calculate the Carnot ceiling: (1 − 323.15/923.15) × 100 ≈ 65.0%.
  3. Calculate reference-phase deviation: |90 − 90| = 0°. At 80° phase the deviation becomes 10°, while the Carnot ceiling stays unchanged.

If the cold temperature rises to 75°C while the hot temperature remains fixed, the ceiling falls to about 62.3%. These values are thermodynamic limits, not measured engine efficiencies or operating-temperature recommendations.

Alpha, beta and gamma layouts

Layout Piston arrangement
Alpha Two sealed power pistons in separate hot and cold cylinders.
Beta A displacer and a power piston in the same cylinder.
Gamma A displacer cylinder connected to a separate power-piston cylinder.

These distinctions describe geometry. They do not by themselves determine power density, price, service life or efficiency. Those require details of the particular engine, heat exchangers, working gas, seals and drive.

Frequently asked questions

Why are there two power pistons?

In an alpha engine, separate hot and cold cylinders each contain a sealed power piston. Their phased volume changes form the defining arrangement shown here.

Does the Carnot result predict shaft efficiency?

No. It is an ideal upper bound from the two absolute temperatures. Heat-transfer limitations, flow losses, leakage and mechanical losses are not calculated.

Why does phase not change the Carnot result?

Carnot efficiency depends only on the hot and cold reservoir temperatures. Phase changes the illustrated piston timing and its deviation from 90°, but this calculator does not turn that change into work or power.

Is 90° always the best crank phase?

It is the reference used here. The best phase for an actual design depends on its volumes, gas path and operating conditions; the phase-error output is not an optimization result.

Can I calculate generator output from these inputs?

No. The calculator has no swept-volume, charge-pressure, speed, heat-transfer or loss inputs. It cannot calculate indicated work or electrical output.

What happens when the cold side is as hot as the hot side?

With equal temperatures the Carnot ceiling is zero. If the entered cold temperature is higher, the display also shows zero for this heat-engine direction; changing labels or operating mode requires a different physical interpretation.

References

Building or designing a mechanism like this?

Explore the precision-engineered motion control hardware used by mechanical engineers, makers, and product designers.

← Back to Mechanisms Index
Share This Article
Tags: