This high-head wheel calculation converts entered steady flow and net head into gross hydraulic power, applies an entered overall efficiency, and divides the resulting illustrative shaft power by a chosen wheel speed.
Related Resources for Actuator Projects
For a separate actuator-driven gate or automation project, check the force application point and changing moment arm before choosing actuator stroke or force. The water-wheel calculator does not calculate gate actuator loads.
When comparing a cylinder to an electric actuator, convert the discussion into stroke, force, speed, duty cycle, and installed length. Matching one specification is not enough.
The actuator stroke should also be checked against the useful motion, not just against the visible travel. End clearance, hard stops, bracket rotation, and wire routing can all reduce the usable stroke in the final build.
- Calculate actuator force at the worst bracket angle, not just at mid-stroke.
- Check stroke, retracted length, and extended length against the mechanism envelope.
- Confirm the structure can accept the higher loads created by a stronger actuator.
For a FIRGELLI actuator application, run the FIRGELLI actuator force calculator, then compare available stroke, force, and mounting envelope in the FIRGELLI linear actuator range. If the goal is to replace an existing unit, use the linear actuator replacement finder before assuming the new actuator is a direct fit.
Water Wheel Form 8 Interactive Calculator
Enter steady flow, net head, assumed overall efficiency and chosen wheel speed. Torque is a power/speed quotient and loss is a calculated difference—not a predicted operating curve or component loss breakdown.
Equation Used
- Water density is 1000 kg/m3 and g=9.81 m/s2.
- Entered flow and net head are steady and simultaneous.
- Overall efficiency is entered and constant.
- RPM is a chosen operating point, not solved from the hydraulic resource.
- Intake, penstock, nozzle, buckets, tailwater, loss breakdown, governing, load and structure are omitted.
High-Head Flow–Head Calculation
The U.S. Department of Energy identifies flow and head as hydropower resource variables. The DOE Microhydropower Handbook provides the standard power equation and efficiency definition.
What This Calculator Represents
The tool evaluates one steady flow-head point, an entered overall efficiency, its arithmetic complement and torque at an independently chosen wheel rate.
Power, Loss Allocation and Torque
P_i=eta P_h
P_loss=P_h-P_i
tau_i=P_i/omega
Loss is a calculated remainder, not a component model.
Worked Scenario
For 150 L/s and 6 m net head, gross hydraulic power is about 8.83 kW. At 65% entered efficiency, illustrative shaft power is about 5.74 kW and arithmetic loss 3.09 kW; at chosen 8 rpm, torque is about 6.85 kN m.
Assumptions and Limits
- Calculated: steady flow-head power, entered-efficiency scaling, remainder and chosen-speed torque.
- Illustrated: high-head admission, wheel and power calculation.
- Not calculated: actual efficiency/speed, loss allocation, hydraulics, governing, load, structure or energy production.
Frequently Asked Questions
Is efficiency predicted?
No.
Is RPM predicted?
No.
Does loss identify where energy goes?
No; it is only P_h minus P_i.
Must head be net head?
Yes for the stated equation.
Are flow changes modeled?
No.
Can this size a real installation?
No.