This page covers the air-lift type of compressed-air water elevator: air enters a submerged riser, and the resulting air-water mixture can rise to a discharge above the external water level. The calculator shows the geometry and static injector pressure. It does not calculate pumping capacity.
Compressed Air Water Elevator Interactive Calculator
Set the outlet height above the external water level and the injector depth below it. The cutaway scales these two distances together, showing the open water intake, separate air feed and continuous delivery riser. Read the submergence fraction and static water pressure. These quantities alone do not determine a workable airflow or water-delivery rate.
Equation Used
- Fresh water, constant density and fixed external water level.
- Discharge is above the surrounding water level and injection is below it.
- Submergence is divided by L + S, not by L alone.
- Airflow, riser bore, friction, drawdown, bubble behaviour and pumping capacity are not inputs or solved outputs.
- The animated mixture illustrates the principle, not a demonstrated operating point.
This is an air-lift geometry and hydrostatic-pressure calculator. It does not predict water flow or establish an operating-pressure range.
The air-lift arrangement
A separate supply pipe carries air down to an injector inside or beside a delivery riser. The riser has an open water intake below the injection point and a continuous route to its outlet. Air entering the water changes the density of the mixed column; operation depends on the complete flow conditions.
USGS Water-Supply Paper 470, Figure 11, illustrates air-lift arrangements with a separate delivery pipe or with the well casing serving that purpose. The animation uses the separate-riser arrangement. It is not a displacement chamber with alternating inlet and exhaust valves.
Two distances define the picture. L runs from external water level up to the outlet. S runs from that level down to the injector. The total injector-to-outlet height is L + S. Pipe widths and equipment details are schematic; the vertical distances share one drawing scale.
Use the calculator to clarify the geometry
Compare different outlet heights and injector depths before moving to a full air-lift performance model. The animation makes the external water level, inlet and outlet distinct so that measured distances are not confused.
Two heights alone cannot establish air demand, water delivery, efficiency or a suitable compressor. These depend on the riser geometry, gas supply, water conditions and pressure losses. The calculator gives no universal “sweet spot” or operating limit based only on submergence.
Submergence fraction and injector pressure
The submerged fraction of the injector-to-outlet height is S/(L + S). Multiplying by 100 displays percent. Dividing S by L answers a different geometric question and is not the fraction used here.
Static water pressure at the injector is ρgS. With fresh-water density 1000 kg/m³ and standard gravity 9.80665 m/s², convert S from feet to metres using 0.3048 and pressure from pascals to psi using 6894.757293168. This gives approximately 0.43353 psi per foot of fresh water.
Absolute pressure adds 101325 Pa, or approximately 14.696 psi, to the gauge pressure. The latter is relative to the atmosphere at the water surface. Neither value includes flow losses or the excess pressure needed to deliver air.
Default geometry: 100 ft lift and 60 ft submergence
The injector-to-outlet height is 100 + 60 = 160 ft. The submerged fraction is 60/160 = 0.375, or 37.5%.
At 60 ft below the external water surface, fresh-water static pressure is approximately 26.01 psig. Adding the reference atmosphere gives approximately 40.71 psia. These are local water-pressure values, not an operating compressor setting.
Increasing outlet height while leaving injector depth unchanged reduces the submergence fraction but leaves the static injector pressure unchanged. Increasing injector depth raises that pressure and increases the fraction. Both changes are visible in the dimensioned cutaway.
What the animation does and does not establish
A larger submerged fraction does not by itself certify useful flow or efficient operation. Changing depth also changes injection pressure; air rate, pipe geometry and losses must be considered together.
The moving bubbles show where air and water travel through the mechanism. Their size, number and speed are illustrative. No output is labelled as a safe, efficient or recommended operating range because this calculator does not solve those conditions.
Questions about the water elevator
Is lift measured from the injector?
No. L is the height above external water level. Add the submerged depth S to obtain injector-to-outlet height.
Why is the default submergence 37.5%?
The submerged 60 ft is divided by the complete 160 ft injector-to-outlet height: 60/(100 + 60).
Why does static pressure stay unchanged when I change lift?
Static water pressure at injection depends on depth below the external water surface. Moving the discharge changes lift but not that depth.
Is injector pressure the required compressor pressure?
No. It is the surrounding static water pressure. Air delivery requires additional pressure and depends on line losses and flow conditions.
Will the pictured arrangement pump at every setting?
The picture is a geometry and flow-path explanation. Pumping performance cannot be determined from these two dimensions alone.
Air-lift reference
USGS Water-Supply Paper 470, printed page 45, Figure 11 (PDF page 47), shows two air-lift layouts. Its description measures submerged length against the distance from the air-pipe bottom to discharge. This page uses that geometric definition without treating historical operating ranges as universal design limits.
Static pressure is derived from ρgS with the water density, gravity, length conversion and reference atmospheric pressure stated above.
Building or designing a mechanism like this?
Explore the precision-engineered motion control hardware used by mechanical engineers, makers, and product designers.