An air-lift system injects compressed air below the external water level into a riser. Before air can enter, its local pressure must exceed the surrounding water pressure. This calculator finds that hydrostatic head and adds two entered allowances for a pressure comparison; it does not calculate pumping capacity.
Compressed Air Lift System Interactive Calculator
Enter the air injector’s depth below the surrounding water level and two pressure allowances. The calculator finds fresh-water hydrostatic pressure, then adds the smaller and larger allowances for comparison. The drawing keeps the receiver above water and shows the injector and riser connection.
Equation Used
- Fresh-water density is 1000 kg/m³; temperature and salinity effects are omitted.
- Depth is measured from the external water surface down to the air injection point.
- The lower and upper totals use the smaller and larger entered allowances respectively.
- The illustrated 5 m above-water riser is a layout assumption, not an entered lift requirement or capability result.
- Zero allowance represents static pressure balance; it does not establish flowing air or water.
Hydrostatic head is calculated from fresh-water density and depth. The two allowances are entered assumptions; they do not establish actual line loss or a suitable operating pressure.
Pressure at the submerged injector
The receiver supplies a small air line that runs down to the injector. Water enters the open riser below, and the air-water mixture can rise toward the outlet when the complete system supports flow. Hiscox Figure 661 illustrates this surface-supply and deep-well arrangement.
Depth h is the vertical distance from the surrounding water surface to the injector. It determines the static water pressure opposing air entry. Depth is not the distance from the ground surface unless the two surfaces happen to coincide.
The diagram shows an illustrative 5 m section above water. That height provides context for the outlet, but it is not an input to this pressure-only calculator and is not a claim that the selected pressures will lift water through it.
Separating static head from allowances
Use the calculator to compare hydrostatic pressure at different injector depths and see the effect of two proposed allowances. The chart separates water head from each allowance instead of treating their sum as a verified equipment setting.
Actual supply selection requires air quantity, piping and valve losses, injector characteristics and the water-lift geometry. The tool does not select a compressor, predict discharge rate or establish pressure ratings.
Hydrostatic pressure in consistent units
Pressure is p = ρgh. With fresh-water density ρ =1000 kg/m³ and g =9.80665 m/s², each metre gives 9806.65 Pa, or approximately 1.42233 psi. The water surface is the gauge-pressure reference.
The lower comparison total is phead + min(A,B), and the upper is phead + max(A,B). Entering the allowances in reverse order therefore gives the same lower and upper totals. The bar conversion is 1 psi =0.0689475729 bar.
An allowance of zero adds no pressure above static balance. It does not account for flow losses or provide a positive pressure difference to drive air through an injector. Positive allowances likewise need validation against the actual system.
Default 20 m comparison
At 20 m below the water surface, fresh-water hydrostatic pressure is 1000 ×9.80665 ×20 =196133 Pa, or about 28.45 psig.
With entered allowances of 10 psi and 15 psi, the comparison totals are 38.45 psig and 43.45 psig. The upper total is about 3.00 bar gauge. These numbers are head-plus-allowance comparisons, not a pump performance test or a recommended operating range.
Changing depth changes all pressure totals. Changing an allowance changes the applicable lower or upper total without altering the water head. The chart makes that separation visible.
Pressure is only part of an air-lift design
Greater submergence increases pressure at injection. It also changes the complete air-lift geometry and two-phase flow, but those effects are not solved here.
Pipe diameter, air delivery, bubble behaviour, drawdown and the height above water all affect operation. The moving bubbles are a flow-path illustration. When both allowances are zero, the drawing remains visible and is labelled static balance rather than showing an established flow.
Questions about injection pressure
Where do I measure depth from?
From the external water surface to the submerged injector, not automatically from ground level.
How much pressure does each metre of fresh-water depth add?
Using 1000 kg/m³ fresh water and standard gravity gives approximately 1.42233 psi per metre. The calculator uses that hydrostatic conversion.
Are the allowances calculated losses?
No. They are entered assumptions. The page shows them separately so they are not mistaken for measured or calculated system losses.
What if allowance A is larger than B?
The calculator sorts them. The smaller is used in the lower total and the larger in the upper total.
Does reaching the displayed pressure guarantee pumping?
No. Pressure, airflow, injector design and the full riser geometry must work together. This tool computes only static head plus entered allowances.
Arrangement reference
Hiscox, Mechanical Movements, Powers, Devices and Appliances, printed page 177, Figure 661 (PDF page 187), illustrates the compressed-air lift system with surface receiver and submerged air feed. Its description distinguishes injector water pressure from the additional conditions needed to raise the mixed column.
The pressure calculation uses the hydrostatic relation ρgh with the explicitly stated fresh-water density and gravity. Use equipment specifications and the complete flow conditions to determine operating limits.
Building or designing a mechanism like this?
Explore the precision-engineered motion control hardware used by mechanical engineers, makers, and product designers.