An air-lift water pump injects compressed air near the bottom of a submerged riser. The air-water mixture in the pipe has a lower average density than the surrounding water, allowing the external hydrostatic head to drive it upward. This calculator separates lift above water level from submergence below it and estimates free-air demand using a selected calibration coefficient.

Compressed Air Lift Interactive Calculator

Set the target water flow, lift above water level and injector depth below it. The cutaway shows the complete air and water paths. The airflow equation uses a selected calibration coefficient; the submergence fraction uses the full injector-to-outlet height.

0°

Estimated free air
--
Air per Gal
--
Submergence fraction
--
Static injector pressure
--

Equation Used

p_s = 0.433 S; Q_air = Q_water L / [C log10((p_s + 14.7)/14.7)]; submergence = S/(L + S).
Use feet, US gallons per minute, psi and free-air cubic feet per minute in this equation. C includes the empirical calibration and unit convention; it is not a dimensionless efficiency percentage. Airflow is referenced to the stated atmospheric basis of 14.7 psi, not the compressed volume at the injector. Hydrostatic pressure omits line/injector losses. The chosen C is not validated against a particular installation, and the equation does not solve two-phase flow or establish reliable capacity.
  • Fresh-water hydrostatic head is approximated by 0.433 psi per foot.
  • Lift L is above the external water level; submergence S is below it.
  • Calibrate the airflow coefficient for the installation before using the estimate to size equipment.
  • Airflow is free-air volume at the atmospheric reference, not local injector volume.
  • The diagram keeps the two heights to one scale; pipe diameters, receiver and bubbles are illustrative.

L is the height above the water level and S is the depth below it. Submergence is S/(L + S). The airflow estimate uses a selected calibration coefficient and is not a verified equipment capacity.

Same mechanism and inputs as the interactive calculator.

Separate air and water paths

A surface air source supplies a small line running down to the injector. Water enters the open lower end of a larger riser. After air is introduced, the mixture rises through that pipe and leaves at the discharge above the surrounding water level.

The cutaway follows the air-lift arrangement illustrated in Hiscox Figure 661. It shows the receiver, descending air line, submerged injector, open water inlet and rising mixture. Pipe widths are enlarged so these separate paths remain visible.

The two relevant heights are L, from water level up to discharge, and S, from water level down to injection. The full injector-to-outlet height is L + S, so the submergence fraction is S/(L + S). A ratio S/L is a different quantity and is not labelled submergence here.

Reading an air-lift layout

USGS describes air-lift pumping in wells using a small air pipe alongside or within the discharge path. The geometry is useful for understanding why the injector must remain below the water level and why water-level changes affect operation.

The calculator is a comparison tool. It does not choose a riser diameter, injector holes, compressor motor, receiver size or stable flow regime. Those require installation-specific flow and loss data.

Geometry, pressure and airflow estimate

The static water pressure at injection is ps = 0.433S psig when S is in feet. Submergence is S/(L + S), expressed as a fraction in the results and a percentage on the diagram.

The estimated airflow is Qair = QwaterL / [C log10((ps + 14.7)/14.7)]. It uses water flow in US gpm, lift in feet and free air in scfm on the stated atmospheric reference. Air per gallon is Qair/Qwater.

C is a calibration coefficient tied to these units and the logarithm convention. It is not a universal dimensionless efficiency. The default value is an example, not a measured coefficient for your pump. The equation does not account separately for bubble slip, riser losses, injector losses or changing flow regime.

Default comparison

At a target of 100 gpm, L = 20 ft and S = 12 ft, the full height from injection to discharge is 32 ft. The submergence fraction is therefore 12/32 = 0.375, or 37.5%, rather than 12/20.

The hydrostatic injector pressure is 0.433 × 12 = 5.196 psig. With coefficient C = 245, the airflow equation gives about 62.1 scfm, or 0.621 scf per US gallon. This is a coefficient-based estimate, not a guarantee of that delivery rate.

Doubling target flow doubles estimated air demand but leaves the geometry and static pressure unchanged. Increasing injector depth changes the water-level position, static pressure and logarithmic pressure ratio. Changing C affects the estimate without changing the physical drawing.

What the diagram does and does not establish

Submergence and lift share one scale in the cutaway. Very shallow submergence remains visible as a short submerged interval instead of being enlarged into a misleading geometry. Bubbles indicate the upward path only.

There is no universal submergence percentage at which every air lift starts, stops or reaches best efficiency. Flow pattern, diameter, depth, injector design and supply conditions all matter. A calculated air quantity and static pressure do not by themselves demonstrate stable pumping.

Questions about air-lift calculations

Is submergence S/L?

No. Here it is S/(S + L), using the submerged height divided by the entire injector-to-outlet height.

Is the displayed air volume at injector pressure?

No. It is free-air volume on the stated atmospheric reference. Compressed volume down the pipe is different.

Is C an efficiency percentage?

No. It is a calibration coefficient tied to the equation’s units and logarithm convention. The selected value needs installation-specific validation.

Does the foot pressure include losses?

No. It is hydrostatic pressure only. Air supply must also overcome pipe, valve and injector losses.

Do moving bubbles prove the selected design will pump?

No. They explain the flow path. The calculator does not solve the two-phase flow or guarantee capacity.

Arrangement and geometry references

Hiscox, Mechanical Movements, Powers, Devices and Appliances, printed page 177, Figure 661 (PDF page 187), shows the surface receiver, air pipe and deep-well riser.

USGS Water-Supply Paper 470, printed page 45 and Figure 11, describes air-lift well arrangements and submergence relative to the injector-to-discharge distance. These references support the layout and height definitions, not a universal value for the airflow coefficient.