The compound Pohle air lift shown by Hiscox uses a first lift to fill an elevated receiving column. A second air lift draws from that receiver and delivers water higher still. The receiving column supplies the second lift’s submergence. This differs from simply adding a second air injector partway up one uninterrupted riser.
Compound Pohle Air Lift Interactive Calculator
Set the sump, receiver and outlet elevations above the common injection plane. See how the receiving column changes the two lifts’ submergence and still-water head.
Equation Used
- Two injection points on one reference elevation.
- Sump and receiver open to atmosphere.
- Fresh-water weight density 62.4 lbf/ft³.
- Specified receiver level maintained; startup and losses outside model.
Intended layout: sump level < receiver level < final outlet. Ratios are geometric; pressure outputs are still-water heads, not compressor ratings.
Two lifts with a receiving column between them
The short riser on the right takes water from the sump. Air introduced near its foot produces an aerated rising column, which discharges into the top of the receiver around the tall riser. Water in that receiver then supplies the tall riser through its lower intake. A second air injection lifts this water to the final outlet.
The two injection points are shown on a common elevation, as in the source arrangement. Their surrounding water levels differ: the first uses the sump level, and the second uses the higher receiver level. A common air supply branches to the two feet. The diagram separates the air pipe, water-filled receiver and aerated risers so the connections remain visible.
Blue markers follow the two delivery paths and gold markers show air entering the feet. These are explanatory markers, not calculated bubble size, gas fraction or flow velocity. The receiver is shown at a steady maintained level; startup filling and entrained-air separation are not dynamically solved.
Why use a receiving column?
Hiscox describes this arrangement for mine drainage where sump depth is limited. Staging uses a receiving column to provide a higher water head for the second lift. It requires additional piping and does not make the compressor energy or required injection pressure disappear.
The historical diagram illustrates the principle. Its suggested sump-to-receiver proportion is not a universal efficiency guarantee. Actual delivery depends on the air supply, riser geometry, gas expansion, bubble slip and flow losses, none of which can be established from three elevations alone.
Use each lift’s own water level
All three inputs are elevations above the common injection plane: sump level S1, receiver level S2 and final outlet H. For the intended two-stage upward arrangement, 0<S1<S2<H.
First-stage submergence ratio is S1/S2. Its net water-level rise is S2−S1. Second-stage ratio is S2/H, and its net rise is H−S2. Percent outputs are 100 times these ratios.
For an open, still fresh-water column with weight density 62.4 lbf/ft³, hydrostatic gauge head at the injection plane is p=62.4S/144 psi. The two displayed heads use S1 and S2 respectively. These are static water-column heads, not compressor ratings or calculated running injection pressures. A water-filled start must overcome local head as well as actual line and injector losses; aeration changes the running pressure profile.
Compare each lift using its own water level, air-injection depth and discharge height. These elevations determine submergence and still-water head; they do not determine compressor airflow, water delivery rate or efficiency.
Example with a common injection plane
Let the sump surface be 40 ft above the injection plane, the receiver surface 80 ft above it, and the final discharge 160 ft above it. The first ratio is 40/80=50%; the second is 80/160=50%.
The first stage raises water level by 40 ft and the second by 80 ft. Still-water head at the two feet is 17.33 psi and 34.67 psi. These values describe geometry and static head only, not an achievable pumping duty.
Raising only the receiver level increases the second-stage ratio but decreases the first-stage ratio. It also increases the still-water head at the second foot. This illustrates the trade without claiming an optimum receiver height.
What remains outside the calculation
The model assumes both sump and receiver are open to atmosphere and uses a constant fresh-water weight density. The selected levels are steady. The risers and air piping are shown with exaggerated widths, and the short outlet spill into the receiver is drawn for clarity.
Airflow, injector pressure drop, pipe friction, two-phase pressure profile, receiver dimensions and water delivery need their own design data. The diagram does not size a compressor or establish pumping efficiency.
If the levels are out of order, the geometry remains visible and the calculator marks it as a layout preview. A ratio above 100% indicates that the selected levels do not describe a normal two-stage upward lift.
Compound air-lift questions
Is the middle level a second injector in the same pipe?
No. Here it is the receiving column’s water surface. The two lift pipes each take water at their lower ends.
Why is the second foot under more water?
It draws from the receiver rather than directly from the sump. That receiver has a higher surface elevation.
Does a 50% ratio guarantee pumping?
No. It describes geometry. The air supply, bubble slip and losses determine whether a real installation delivers water at the required rate.
Are the pressure outputs a compressor recommendation?
No. They are still-water gauge heads at the two injection points. They omit operating losses and the aerated pressure profile.
Why can the diagram remain visible for crossed levels?
It shows what the selected elevations mean. A layout-preview message distinguishes that drawing from the intended two-stage upward operation.
Why are the pipes so wide?
Widths are exaggerated so air and water routes remain legible. Elevations follow the inputs; pipe diameters are not inferred from them.
Historical source
Gardner D. Hiscox, Mechanical Movements, Powers, Devices and Appliances, expanded edition, printed page 187, figure 698: compound Pohle air lift with a receiving column and two lifts. The submergence ratios and still-water heads here follow the displayed elevations, and describe geometry and hydrostatic head only.
Building or designing a mechanism like this?
Explore the precision-engineered motion control hardware used by mechanical engineers, makers, and product designers.