Pneumatic Paint Sprayer: Connected Air/Fluid Paths and Free-Air Cycle Ledger

← Back to Engineering Library

This revision removes an arbitrary safety factor and the claim that duty-averaged airflow alone prevents pressure sag. It shows the connected gun topology and balances declared gun and compressor free-air volumes over one explicit trigger-on and recovery-off cycle.

Spray-Gun Free-Air Cycle Explorer

Enter declared gun FAD consumption, compressor FAD, trigger-on duration and recovery-off duration at matching reference conditions and rated pressure. The worksheet reports gun volume per cycle, balance FAD, net reserve change and trigger-on drawdown.

0°

Gun air per cycle
--
Cycle-balance FAD
--
Net reserve change
--
Trigger-on drawdown
--

Equation Used

V_gun=Q_gun t_on/60; Q_balance=Q_gun t_on/(t_on+t_off); Delta V=Q_comp(t_on+t_off)/60-V_gun; V_draw=max(0,(Q_gun-Q_comp)t_on/60)
This is a free-air-equivalent volume ledger at declared matching reference conditions. It does not calculate receiver pressure, hose drop, regulator behavior, cap pressure, atomisation, compressor duty or equipment selection.
  • Gun consumption and compressor FAD are declared at compatible free-air reference conditions and the required operating pressure.
  • Gun consumption is constant while the trigger is on and zero during the declared off interval.
  • Compressor FAD is constant over the declared cycle.
  • Positive net reserve change means delivered free-air equivalent exceeds declared cycle consumption; it does not prove a pressure limit is maintained.
  • Trigger-on drawdown is the volume shortfall when instantaneous gun consumption exceeds compressor FAD; usable receiver reserve is not inferred.
  • Receiver size and pressure bounds, compressor controls and duty, hose/regulator/filter losses, leaks, temperature, atomisation, liquid flow, coating properties, fan pattern, transfer efficiency, ventilation, fire/explosion controls, PPE, ratings and safe operation are excluded.

Replaces an arbitrary safety-factor sizing claim with an exact declared trigger-cycle free-air volume balance and connected air/fluid gun topology.

Air and coating meet at the nozzle and air cap

Graco's air-spray-gun documentation identifies separate air and fluid supplies, a fluid needle and nozzle, and an air cap. The connected section follows those paths: the trigger opens the air path and retracts the fluid needle; coating exits centrally while centre and horn-port air surround the nozzle.

The animated fan and droplets only trace those paths. They do not predict droplet size, fan dimensions or finish quality.

Air use, pressure and components are gun-specific

Graco publishes air-cap-specific consumption at stated inlet pressure, along with matched needle/nozzle combinations and model pressure limits. SATA likewise publishes different air consumption and inlet-pressure ranges by gun. Use the exact current gun, cap, nozzle and coating data.

Balance free-air-equivalent volumes over an explicit cycle

V_gun=Q_gun t_on/60; Q_balance=Q_gun t_on/(t_on+t_off)

Gun consumption times trigger-on time gives declared free-air volume used. Compressor FAD times the full cycle gives delivered free-air volume. Their difference is the net reserve change. During the trigger-on interval, any positive difference Q_gun-Q_comp must come from declared system reserve.

A transparent declared-cycle example

A gun declared at 400 L/min for a 30 s pass consumes 200 L free-air equivalent. With 30 s recovery, cycle-balance FAD is 200 L/min. A compressor declared at 300 L/min delivers 300 L over the full 60 s cycle, so net reserve change is +100 L, while the trigger-on shortfall draws 50 L before recovery.

Average cycle balance does not prove stable spray pressure

Even with positive full-cycle balance, the receiver and piping must supply the trigger-on shortfall while remaining within required pressure bounds. Receiver state, compressor controls, duty, hose, regulator, filter and fitting losses, leaks and simultaneous users are not modeled.

The former safety factor does not quantify those effects and is removed. This page also does not predict atomisation, transfer efficiency, coating flow or finish, and it does not design ventilation, grounding, fire/explosion control or PPE. Follow the coating, gun and facility safety requirements.

Spray-gun airflow worksheet questions

Is cycle-balance FAD enough for a continuous pass?

Not by itself. The trigger-on shortfall must come from usable reserve while pressure remains within limits.

Does positive net reserve change select a compressor?

No.

Do the droplets predict atomisation?

No. They only trace the connected paths.

Are L/min values interchangeable without reference conditions?

No.