A spray nozzle converts pressure into a liquid jet and then shapes or atomizes that jet through its internal geometry. This calculator evaluates a selected steady-water sharp-orifice proxy and a separate straight-ray width construction. It does not predict an actual nozzle's flow, spray pattern, droplet size or coverage.
Spray Jet Nozzle · Selected Water-Orifice Proxy
Explore a selected steady-water orifice-flow proxy and a separate straight-ray width construction.
Equation Used
- The liquid is water with density fixed at 998 kg/m³.
- Pressure is the steady pressure difference across the selected orifice proxy.
- Cd is selected by the user and held constant when pressure is doubled.
- The orifice-area model is incompressible and one-dimensional.
- The width construction treats the entered full angle as two straight rays from the nozzle at half-angle.
- Actual passages, viscosity, Reynolds-number dependence, turbulence, cavitation, atomization, droplets, pattern uniformity, overlap, wind, gravity, fluid changes, product tolerances and safety are excluded.
The former undisclosed 0.4 GPM normalization is removed. Water density is fixed at 998 kg/m³ and Cd is an explicit user selection.
Selected water-orifice proxy
For water density fixed at 998 kg/m³, the ideal pressure speed is sqrt(2 deltaP/rho). The entered discharge coefficient Cd scales both mean exit-speed and volume-flow proxies. A separate geometric construction projects the entered full angle from the entered height.
What the calculator determines
Use it to explore the square-root pressure relationship, orifice-area scaling, a selected discharge coefficient and a nominal straight-ray width. Compare any real nozzle only with manufacturer test data for that exact nozzle and operating fluid.
Exact selected relationships
A=pi d²/4; videal=sqrt(2 deltaP/rho); Qproxy=Cd A videal; vproxy=Cd videal; Q2x=sqrt(2) Qproxy; Wstraight=2h tan(theta/2).
Selected-input example
At d=1.00 mm, deltaP=40 psi and Cd=0.61, the model evaluates the disclosed water-orifice equations. At a selected 65° full angle and 30 in height, the separate straight-ray construction gives a nominal width; that width is not measured spray coverage.
Not a nozzle-performance model
The proxy excludes the actual inlet and internal passages, viscosity, Reynolds-number effects, turbulence, cavitation, atomization, droplet spectrum, pattern uniformity, overlap, wind, gravity and fluid-property changes. Cd is selected by the user rather than inferred for a product.
Questions
Does the calculated flow rate specify a real nozzle?
No. It is a selected sharp-orifice water proxy; use tested manufacturer data for a real nozzle.
Is the straight-ray width actual coverage?
No. It is only trigonometric projection of the entered angle and height.
Does doubling pressure double flow?
Not in this fixed-Cd incompressible proxy: the flow scales with the square root of pressure, so doubling pressure multiplies it by sqrt(2).
References & Further Reading
- Wikipedia contributors. Spray nozzle. Wikipedia
Continue exploring engineering
Find another tool, explore an animated mechanism, or browse resources by subject.
Building or designing a mechanism like this?
Explore the precision-engineered motion control hardware used by mechanical engineers, makers, and product designers.