A mechanical windmill turns rotor motion into an up-and-down pump stroke. Explore the connected crank, sucker rod and pump cylinder, then calculate displacement and flow from cylinder dimensions and an entered stroke rate.
Windmill Pump Displacement Calculator
Enter pump-cylinder bore, stroke, measured stroke rate, an entered volumetric factor and lift head. The worksheet reports swept volume, theoretical and adjusted flow, and water power; it does not predict windmill output.
Equation Used
- Cylinder bore and stroke define a single ideal displaced volume.
- Entered strokes per minute are measured or otherwise supplied, not inferred from wind speed.
- Entered volumetric factor aggregates leakage and incomplete fill without diagnosing them.
- Rotor torque, wind statistics, gearing, rod stretch, valve dynamics, friction, furling and safe lift are excluded.
Cylinder bore and stroke determine swept volume. Multiplying by the supplied pumping rate gives theoretical flow; the entered volumetric factor adjusts that flow for assumed leakage and filling losses.
Rotor, gearbox, sucker rod and piston pump
Aermotor and USDA descriptions show the wind rotor driving a geared conversion to an up-and-down sucker rod. The rod moves a plunger in a cylinder; check valves make water advance upward through the drop pipe.
The animation preserves that connected motion but does not infer stroke rate from wind.
A displacement and measured-rate worksheet
Use the calculator after selecting or measuring a stroke rate. Volume and flow outputs use US gallons. Real windmill selection should use manufacturer or NRCS capacity/head tables for the exact wheel, stroke, cylinder and rod system.
Piston displacement
Displacement example
A 3-inch bore, 12-inch stroke pump displaces 0.367 gallon per stroke. At 20 strokes/min it gives 440.6 gal/h theoretical; an entered 75% factor gives 330.5 gal/h and 103.9 W of water power at 100 ft head.
Relating pump displacement to windmill output
A wind-to-water performance curve depends on the actual mill's torque, gearing, pump and furling behavior. Manufacturer and NRCS capacity tables are configuration-specific; the displacement calculation here starts with a supplied stroke rate rather than predicting it from wind speed.
Windmill-pump calculation questions
Does this predict flow from wind speed?
No.
Is the volumetric factor universal?
No; it is an entered assumption.
Is water power input shaft power?
No. It is hydraulic output based on entered adjusted flow and head.
Wind-pump references
- Aermotor, How a Windmill Pumps Water: rotor, gearing, sucker rod, plunger and check-valve sequence.
- USDA NRCS National Engineering Handbook, Irrigation Pumping Plants: positive-displacement windmill pump and valve operation.
- USDA NRCS Windmill Data Sheet: configuration-specific cylinder capacities and pumping elevations.
Building or designing a mechanism like this?
Explore the precision-engineered motion control hardware used by mechanical engineers, makers, and product designers.