Hydraulic Model Turbine: Ideal Speed and Discharge Similitude

← Back to Engineering Library

A hydraulic turbine model represents a larger machine at reduced geometric scale. Compare model and prototype speed and discharge using ideal similarity relationships at corresponding operating points.

Ideal Turbine Similitude Calculator

Enter model/prototype reference diameters and heads plus model speed. The worksheet reports the ideal homologous prototype speed and discharge ratio; it does not predict efficiency, power, cavitation, loads or acceptance-test results.

0°

Prototype/model diameter
--
Ideal prototype speed
--
Prototype/model discharge
--
Model unit speed ND/sqrt(H)
--

Equation Used

N11=ND/sqrt(H); Np=Nm(Dm/Dp)sqrt(Hp/Hm); Qp/Qm=(Dp/Dm)^2 sqrt(Hp/Hm)
The equal-unit-speed and equal-unit-discharge relationships assume geometrically similar machines at corresponding guide-vane and runner settings. Real transposition requires the applicable standard, measurements and scale-effect treatment.
  • Model and prototype are geometrically similar and compared at homologous operating points.
  • Reference diameters use the same definition for model and prototype.
  • Heads are positive net heads and model speed is steady.
  • Efficiency, Reynolds effects, roughness, cavitation coefficient, uncertainty, power, torque and structural loads are excluded.

Ideal similarity relates speed and discharge through diameter and net head. Efficiency, cavitation and scale effects require additional measurements and analysis.

Geometric similarity and homologous operation

A laboratory turbine model reproduces the prototype's hydraulic passages at a consistent geometric scale. At corresponding settings, equal unit speed relates rotational speed, reference diameter and net head; equal unit discharge relates flow, diameter and head.

IEC 60193 covers far more than these two identities: test arrangements, measurements, computation, uncertainty, comparison with guarantees and scale effects.

Ideal model-to-prototype scaling

Use the calculator to compare ideal speed and discharge ratios before a detailed test plan. Do not use it to guarantee prototype power, efficiency, cavitation performance, runaway behavior or structural adequacy.

Ideal homologous scaling

N11=ND/sqrt(H); Q11=Q/(D^2 sqrt(H))

Equating N11 and Q11 between model and prototype produces the displayed prototype speed and discharge ratio.

Scaling example

For Dm=0.30 m, Dp=6.0 m, Hm=30 m, Hp=120 m and Nm=1200 rpm, the diameter ratio is 20, ideal prototype speed is 120 rpm, discharge ratio is 800 and model unit speed is 65.7 rpm m/sqrt(m).

Limits of ideal similarity

IEC 60193 treats model-to-prototype conversion, scale effects, measurements and uncertainty as part of model acceptance testing. The two ideal similarity identities alone cannot determine efficiency gains, roughness losses, cavitation performance or financial outcomes.

Model-turbine questions

Does equal unit speed guarantee equal efficiency?

No. Efficiency transposition and scale effects are separate analyses.

Is discharge ratio a measured flow?

No. It is the ideal ratio under the stated similarity assumptions.

Does this replace IEC 60193 testing?

No.