The Fourneyron turbine is an outward-flow reaction water turbine. Water passes from a central inlet through stationary guide vanes and then outward through an annular rotating runner. The calculator estimates water power, shaft power and torque from entered head, flow, efficiency and speed; it does not predict a particular runner’s performance curve.
Fourneyron Turbine Interactive Calculator
Vary head, flow, efficiency, and speed to see hydraulic power, shaft output, horsepower, and runner torque.
Equation Used
The calculator uses the standard hydropower relation for a reaction turbine: water power is rho g Q H, and shaft power is that value multiplied by overall efficiency. Torque is then found from shaft power divided by angular speed.
- Water density is fixed at 1000 kg/m3.
- Gravity is fixed at 9.81 m/s2.
- Efficiency represents all hydraulic and mechanical losses combined.
- Steady flow at the selected head and speed.
Water moves outward through the runner
The stationary distributor directs water toward the inner edge of the surrounding runner. Water then travels to a larger radius through the moving blade passages. Pressure and velocity change through the reaction runner, and the change in the water's angular momentum produces shaft torque.
Guide-vane angles, runner geometry and speed determine the velocity relationship at entry and exit. Head and flow alone do not determine those angles or the best operating speed. The illustration shows their arrangement but does not solve the fluid velocity triangles.
Blue markers move outward within the illustrated guide and runner passages. Markers in the runner follow its rotating passages; they show flow direction rather than computed water trajectories. The fixed blade counts and curves illustrate the arrangement rather than a particular historic casting. Speed changes the slowed runner playback, and flow changes marker travel rate. Head, flow and efficiency determine the displayed energy balance. Cavitation and shock losses are not simulated.
Outward-flow waterpower
Fourneyron's radial reaction arrangement belongs to the development of industrial water turbines. It provides a useful comparison with inward-flow and axial-flow designs: the direction of travel through the runner and placement of the distributor are visibly different.
For restoration, use the original installation's drawings and measured characteristics. For a new hydropower site, turbine choice depends on net head, available flow and its variation, efficiency, setting and project requirements. The simple energy balance does not select a Fourneyron, Francis or Kaplan machine or establish a retrofit cost.
Energy balance and shaft torque
Water power is Pw = ρgQH. The model fixes density ρ at 1,000 kg/m³ and gravity g at 9.81 m/s². Q is flow through the turbine in m³/s and H is net head across it in meters. Dividing watts by 1,000 gives kilowatts.
Shaft power is Ps = ηPw, with efficiency entered as a percentage and converted to a fraction. Here η covers hydraulic and mechanical losses up to the shaft. It does not include a separate electrical generator unless you deliberately include that stage, in which case the shaft label and torque interpretation would no longer describe the same output location.
For the stated shaft interpretation, angular speed is ω = 2πN/60 radians per second, and mean torque is T = Ps/ω with power in watts. Mechanical horsepower is shaft kilowatts divided by 0.745699872.
Efficiency is an assumption, not calculated from blade geometry, head, flow or speed. Changing speed alone therefore leaves the calculated power unchanged and changes torque inversely. A real runner's operating point and efficiency can change at the same time; this tool supplies no load curve, runaway speed, stall torque or cavitation limit.
Example: the default operating assumptions
Enter net head 10 m, flow 0.5 m³/s, overall shaft efficiency 80% and speed 300 RPM. Water power is 1,000 × 9.81 × 0.5 × 10 = 49,050 W, or 49.05 kW.
Shaft power is 0.8 × 49.05 = 39.24 kW, approximately 52.62 mechanical hp. Angular speed is 31.416 rad/s, giving mean shaft torque approximately 1,249 N·m.
If speed changes to 600 RPM while all other assumptions remain fixed, torque halves to about 625 N·m and power stays 39.24 kW. This is an arithmetic comparison, not proof that the turbine can operate at both points with the same efficiency.
The low settings H = 1 m, Q = 0.05 m³/s and η = 40% give 0.1962 kW shaft output. H = 50 m, Q = 5 m³/s and η = 90% give 2,207.25 kW. These independently entered extremes are not ratings of the illustrated runner.
What this estimate leaves open
The energy balance is useful for checking how available head and flow relate to an assumed shaft output. It cannot establish peak efficiency, seasonal energy yield or which blade geometry will achieve the assumption.
Compare real candidate machines using performance data over the site's operating range. Bearings, intake losses, debris, tailwater, flow regulation and the driven load also matter. A discrepancy between measured and estimated power is not enough to identify a worn vane, cavitation or a particular repair.
Frequently asked questions
Does the tool calculate Fourneyron efficiency?
No. Efficiency is entered. The model does not change it automatically with head, flow or speed.
Should Head be gross or net head?
Use net head across the turbine for the stated turbine-to-shaft efficiency. Account for upstream and downstream system losses consistently rather than counting them twice.
Why does changing speed not change power?
The energy calculation uses head, flow and the entered efficiency. Speed only converts that power into torque and changes playback. A physical performance curve may behave differently.
Is Shaft Power electrical output?
No. The stated efficiency ends at the shaft. A coupled generator would add its own conversion losses.
Does more flow always give proportionally more real output?
Only in this calculation when head and efficiency are held constant. Actual head, efficiency and machine limits can change with flow.
Can the model size runner blades or guide-vane angles?
No. It has no blade dimensions or velocity-triangle solution.
Does the animation show actual water particle paths?
No. The outward-moving markers illustrate the flow direction, not solved streamlines or blade contact.
Can I infer a safe speed or a repair from the result?
No. The tool provides an energy balance and mean torque estimate, not mechanical limits, fault diagnosis or a maintenance procedure.
Waterpower references
Building or designing a mechanism like this?
Explore the precision-engineered motion control hardware used by mechanical engineers, makers, and product designers.