Jacketless Carriage Motor: Illustrative Fin-Cooling Calculator | FIRGELLI

← Back to Engineering Library

This calculator is a hypothetical fin-area sensitivity model built around an assumed 0.42 m² reference area. It applies ideal convection arithmetic; it does not reproduce or approve a historical engine cooling system.

Jacketless Gasoline Carriage Motor Interactive Calculator

Explore how assumed fin-depth and spacing multipliers, an entered heat-transfer coefficient and wall-to-air temperature difference affect an ideal convection estimate.

0°

Ideal Convection
--
Assumed Effective Area
--
Positive Wall−Air ΔT
--
Ideal Convective Flux
--

Equation Used

Aproxy=0.42(d/28)(6/s); positive DeltaT=max(0,Twall-Tair); Qideal=h Aproxy DeltaT; q''=h DeltaT
Hypothetical reference-area scaling and ideal lumped convection only.
  • 0.42 m² is an assumed effective-area reference at d=28 mm and s=6 mm.
  • Effective area scales linearly with fin depth and inversely with spacing solely for sensitivity comparison.
  • Entered h is a uniform user assumption and entered air temperature is a uniform bulk-air value.
  • The temperature driving force is clipped at zero; radiation and inward heat flow are not modeled.
  • No base circumference, fin count/thickness/profile, conduction, fin efficiency, contact resistance, airflow distribution, radiation, combustion heat balance, engine power, transient temperature, material limit, lubrication, strength, restoration or safety model.

The 0.42 m² reference area is an assumption, not a measurement of a particular engine. Depth/spacing scaling omits cylinder dimensions, fin thickness and fin efficiency. The bulk air temperature is the fluid temperature used in Q=hA(Twall−Tair); it is not a measured fin-tip temperature.

Opposed-cylinder motor with cooling fins; numeric total area follows a separate assumption.

Idealized fin cooling comparison

Heat can conduct from a hot cylinder wall into external fins and then transfer to surrounding air. This calculator stops at a lumped convection identity Q=hA DeltaT and an explicitly assumed effective-area scaling.

Hiscox item 856 shows a jacketless carriage motor with two opposed cylinders, opposite crank throws and simultaneous combustion. The cutaway illustrates its pistons, connecting rods, crankshaft and radial cooling fins. The proportions are illustrative, and valve gear is omitted. It does not calculate temperatures along the fins.

Use as a sensitivity exercise

The sliders show how the stated assumptions affect simple arithmetic. They cannot verify an engine's cooling capacity, safe temperature, continuous power, fin geometry, airflow or restoration condition.

Assumed proxy, not geometric area

Aproxy=0.42(d/28)(6/s) m² uses 0.42 m² at 28 mm depth and 6 mm spacing as an unverified reference. It is not derived from cylinder circumference, fin count or thickness. With positive DeltaT=max(0,Twall−Tair), ideal convection is Q=hAproxy DeltaT and ideal flux is h DeltaT.

Worked example

At the reference d=28 mm and s=6 mm, assumed area is 0.42 m². With h=100 W/m²·K, wall 250 °C and bulk air 80 °C, positive DeltaT is 170 K, ideal convection is 7.14 kW and ideal flux is 17.0 kW/m². These are assumption-driven values, not a measured engine result.

Limits of the convection estimate

Actual cooling depends on fin geometry, thermal conductivity, airflow and temperature variation through the metal. Radiation and the engine’s heat input also matter. This calculation does not determine those effects or establish an engine operating temperature or power rating.

Frequently asked questions

Is 0.42 m² a measured historical engine area?

No. It is an arbitrary reference for this sensitivity calculation.

Is the calculated kW an engine rating?

No. It is ideal convection based on the assumed area, entered coefficient and temperature difference.

Why enter bulk air temperature?

Convection depends on the difference between surface and surrounding-fluid temperatures. Real fins vary in temperature and require a separate fin-efficiency calculation.

What happens if the air is hotter than the wall?

The output is clipped to zero. Heat flowing into the wall is not represented by this calculator.

References & Further Reading

Gardner D. Hiscox, Mechanical Movements, Powers, Devices and Appliances (1901), page 221, item 856: jacketless gasoline carriage motor.

  • Wikipedia contributors. De Dion-Bouton. Wikipedia

Building or designing a mechanism like this?

Explore the precision-engineered motion control hardware used by mechanical engineers, makers, and product designers.

← Back to Mechanisms Index