Ancient water lifts raise water for irrigation, drainage or supply using levers, containers, wheels or screws. This animation focuses on an inclined Archimedean screw rotating in a stationary trough. The calculator estimates discharge from entered pocket volume, pockets delivered per revolution, volumetric efficiency and rotational speed. It does not size the screw or its drive.
Ancient Water Lift Interactive Calculator
Compare screw water-lift discharge from entered volume per pocket, pockets per turn, volumetric efficiency and speed. Geometry, power and lift height are not calculated.
Equation Used
The Archimedes screw discharge is estimated by multiplying volumetric efficiency, pocket volume, pockets per turn, and revolutions per second. Higher speed, larger pockets, or more pockets per turn increase flow, while leakage and backslip reduce it through eta_v.
- Steady screw rotation with constant pocket filling.
- Volumetric efficiency includes leakage and backslip.
- Pocket volume is the water volume trapped per pocket.
- Inclination and screw dimensions are not inputs; their effects must already be represented by the entered pocket volume and efficiency.
The screw water lift
Rotating helical flights form water pockets against an inclined trough. Water enters at the lower end, travels upward through successive positions along the screw and leaves at the upper outlet. The trough remains stationary in the illustrated arrangement.
The animation enlarges the pockets to make the movement visible. Its drawn flights illustrate the principle; they do not establish a manufacturable pitch, diameter, clearance or number of starts. Playback runs at half the entered rotation speed, while numerical flow uses the full entered speed.
Parts shown
- Lower inlet: supplies water to the screw.
- Shaft and flights: rotate to carry water upward.
- Stationary trough: confines the water around the flights.
- Upper outlet: receives the lifted water.
The drive supplies the energy needed for lifting and losses. A counterweight in another type of lift, such as a shaduf, can balance part of the load but is not a continuing source of energy over repeated cycles.
Several ways to raise water
A shaduf lifts a bucket with a counterweighted lever. A water-powered noria carries containers around a wheel rim. Animal-driven lifts can use gearing and a wheel or chain of containers. A screw lift carries water in helical pockets. These are different mechanisms, even when they serve the same irrigation or drainage task.
Choosing among them depends on available power, water levels, required delivery, site geometry and maintenance. Historical appearance does not by itself establish flow, operating cost or suitability for a modern installation. The calculator on this page applies only to the entered screw-delivery model.
From volume per revolution to flow
Let ηv be the entered Efficiency percentage divided by 100, Vp be Pocket Volume in litres, Np be Pockets / Turn and N be Screw Speed in rpm. Delivered volume per revolution is ηvVpNp in L/rev. Flow Rate Q is ηvVpNpN/60 in L/s.
Hourly Flow is 3.6Q in m³/h. Daily Volume is Hourly Flow × 24 in m³/day, assuming uninterrupted operation at the same flow. It includes no downtime or variation in source water.
Pockets / Turn means effective pocket deliveries per complete revolution, not the number of water pockets visible along the whole screw. Pocket volume and the efficiency allowance must use a consistent definition so that filling or leakage losses are not counted twice.
The formula multiplies entered quantities. It does not derive efficiency from rpm, inlet immersion, inclination or clearance. Increasing speed therefore increases calculated flow in direct proportion while efficiency stays fixed. Real operation can depart from that relationship.
Hydraulic lifting power would require flow, water density and vertical head. Shaft input also requires mechanical and hydraulic loss information. Since head and drive losses are absent, the flow result cannot specify a motor.
Worked example: assumed screw delivery
Use Efficiency 80%, Pocket Volume 38 L, Pockets / Turn 3 and Screw Speed 20 rpm. Delivered volume per revolution is 0.80 × 38 × 3 = 91.2 L/rev. Flow is 91.2 × 20/60 = 30.4 L/s.
Hourly flow is 30.4 × 3.6 = 109.44 m³/h, displayed as 109.4. Continuous daily volume is 2626.56 m³/day, displayed as 2627. Those totals assume water and drive power remain available for the full period.
At 10 rpm with other inputs unchanged, flow halves to 15.2 L/s, hourly flow becomes 54.72 m³/h and volume per revolution remains 91.2 L. At 20 rpm and Efficiency 60%, flow becomes 22.8 L/s. These changes follow the entered assumptions; they do not predict how a specific screw’s efficiency varies.
The example is numerical, not a report from a heritage installation or a motor-selection calculation.
What a delivery estimate leaves out
A lever lift delivers separate bucketfuls. A wheel or container chain delivers successive batches. A screw can provide a steadier stream through repeated pocket delivery. Each needs a suitable power source and a path from the lower water level to the discharge.
For an actual design, geometry establishes reach and pocket capacity; the inlet determines filling; leakage, bearings and the drive affect performance. Inspection intervals, clearances and permissible speeds belong to the specific construction. They cannot be inferred from the calculator’s slider ranges.
Water-lift calculation questions
No. It is a volumetric delivery factor applied to the entered pocket volume and number of deliveries. It does not calculate shaft power or electrical consumption.
No. Efficiency is an independent input. The formula assumes it stays at the entered value, even though real filling and leakage may change with speed.
Use effective pocket deliveries per complete revolution, consistent with the definition of entered pocket volume. Do not count every pocket visible along the screw as a separate delivery per turn.
That output is efficiency times pocket volume times pockets per turn. Speed changes how many revolutions occur per second, not that assumed delivery per revolution.
No. It multiplies the hourly flow by 24 and assumes continuous operation with an unchanged water supply and operating point.
No. Head, input power, losses, starting torque and drive characteristics are not calculated. Volumetric efficiency alone is insufficient for drive sizing.
No. Actual filling, leakage, water levels, geometry and measurement all need examination. One low-flow observation does not identify a unique fault or justify a universal clearance limit.
It assists balance during part of the motion. Over a repeated cycle, the operator or another power source must supply the net energy used to raise water and overcome losses.
References and further reading
FAO: Water Lifting Devices surveys lifting mechanisms and power sources. Its discussion of direct lifts and pumps provides context for bucket, wheel and screw arrangements. Use construction-specific information for an actual installation.
Building or designing a mechanism like this?
Explore the precision-engineered motion control hardware used by mechanical engineers, makers, and product designers.