Archimedes' Screw Mechanism: How It Works, Parts, Formula, Diagram and Calculator

← Back to Engineering Library

An Archimedes screw lifts water in pockets between helical flights, a central shaft and an inclined trough or casing. Rotation carries the pockets toward the upper outlet. The animation shows this motion, and the calculator compares a simplified annular volume at a fixed 50% fill assumption.

Archimedes' Screw Interactive Calculator

Explore an annular-volume estimate and an inclined multi-start screw. Helix lead is the axial distance along one flight per turn.

0°

Sector volume
--
Filled / Rev
--
Flow Rate
--
Flow Rate
--

Equation Used

A = pi(D²-d²)/4; V_sector = A·P/N; V_rev = 0.50·V_sector·N; Q = V_rev·rpm/60
The annular volume over one lead is divided among N starts, so adding starts does not multiply that same volume N times. A fixed 50% fill factor gives only a rough displacement comparison, not a hydraulic pump prediction.
  • One lead P is the axial advance of a single helix in one revolution.
  • Starts divide the annular volume; actual bucket fill also depends on inclination, water level, blade count and geometry.
  • The illustrative fixed fill factor is 0.50. Leakage, blade thickness and inlet/outlet conditions are omitted.
  • Shaft diameter must be smaller than outer diameter.

The shaft diameter must be smaller than the outside diameter for flow results. An overlapping shaft remains visible as a labeled geometry preview.

Watch the Archimedes' Screw in motion
Related video: Archimedes screw pump. Compare the rotating flights and upward water transport with the illustration.
The reference drawing uses the selected screw dimensions and start count.

Rotating flights and rising water pockets

The lower end of the screw meets the water source. Adjacent flights and the surrounding trough create spaces where water can collect. As the screw rotates, those pockets progress uphill and discharge at the upper end. Gravity keeps the water toward the lower part of each pocket.

The trough is stationary in the arrangement shown, so the flight tips need clearance. The pockets are not perfect seals: water can leak back, and inlet level, outlet conditions and inclination affect filling. The blue markers illustrate pocket transport rather than a fluid-flow simulation.

Dimensions and parts

  • Outer diameter D: sets the flight-tip envelope.
  • Shaft diameter d: occupies the central part of that envelope.
  • Helix lead P: the axial advance of one flight through a full turn.
  • Starts N: the number of interleaved helical flights.
  • Stationary trough: surrounds the lower part of the rotating assembly.
  • Bearings and drive: support and rotate the screw.

For evenly spaced starts, the spacing between adjacent flights along the axis is P/N. That distinction matters: adding starts at unchanged lead divides the same annular region rather than multiplying its volume.

Water lifting and related machines

Screw pumps are used in drainage and water-handling installations. Spaans Babcock’s design guidance treats diameters, flight count, inclination, pitch, speed and clearance as interacting parameters. Its inlet and outlet reference levels also matter to pump selection. A geometry-only displacement comparison does not capture these effects.

A screw turbine uses falling water to drive rotation and extract energy. A screw conveyor moves bulk material with related helical geometry. These machines need different performance models; the water-volume calculation here does not predict turbine output or solids throughput.

Solids tolerance and fish passage depend on a particular machine and installation. The animation does not establish that a screw passes every obstruction or is suitable for live-fish transfer.

The annular-volume comparison

With dimensions in meters, annular area A = π(D² − d²)/4. Sector volume = AP/N. Filled / Rev = 0.50 × Sector volume × N = 0.50AP. Flow Rate Q = (0.50AP) × rpm/60 in m³/s; multiply by 1000 for L/s.

Sector volume is an arithmetic division of the annular volume over one lead, not a calculation of a real water bucket’s free surface. The 0.50 factor is a fixed illustration, not a measured hydraulic efficiency. Actual filling can change with flight count even though N cancels from this simplified expression.

At fixed D, d and P, changing Starts changes the sector-volume tile and drawing but leaves Filled / Rev and both flow tiles unchanged. Changing rpm scales the estimated flow linearly. There is no speed-dependent leakage, filling loss or power calculation.

If d is equal to or greater than D, the model reports invalid diameters and leaves numerical flow unavailable. The preview still shows the selected geometry. The drawing’s 26° inclination is illustrative; angle, length and inlet/outlet levels are not calculation inputs.

Worked example: three starts at fixed lead

Enter D = 1.6 m, d = 0.7 m, P = 1.6 m per turn, N = 3 and speed 35 rpm. Annular area is π(1.6² − 0.7²)/4 = 1.625774 m². Sector volume is 1.625774 × 1.6/3 = 0.867080 m³.

Filled / Rev = 0.50 × 0.867080 × 3 = 1.300619 m³/rev. At 35 rpm, Q = 1.300619 × 35/60 = 0.758695 m³/s, or 758.695 L/s before display rounding.

At 20 rpm the same estimate is 0.433540 m³/s, or 433.540 L/s. At 60 rpm it is 1.300619 m³/s, or 1300.619 L/s. These are results of the fixed-fill model, not a pump curve or recommended operating range.

Changing N from 3 to 1 triples Sector volume to 2.601239 m³ but leaves Filled / Rev and flow unchanged in this model. It does not prove that one-flight and three-flight real pumps perform identically.

Different jobs for helical machines

Machine Energy and material movement
Screw pump A drive lifts water toward a higher outlet.
Screw turbine Descending water supplies mechanical power.
Screw conveyor A drive transports bulk solids.

Choosing among pump types requires the actual duty and manufacturer performance data. This calculation supplies no universal efficiency, debris tolerance, operating speed, maintenance interval or service-life ranking.

Screw-volume questions

Sector volume is divided by N and then multiplied by N in the per-turn calculation. At fixed diameters and lead, those factors cancel. Real hydraulic filling is more complex.

No. It is AP/N, an annular-volume division. A real bucket’s free surface and spill conditions are not calculated.

No. It is a fixed volumetric fill assumption. It does not relate shaft power to hydraulic power.

A shaft equal to or larger than the outer diameter leaves no valid annular space in this model. The preview remains visible so the geometry can be adjusted.

No. Inclination is illustrative and the numerical flow stays linear with rpm. It has no optimization or speed-dependent hydraulic model.

No. Gap, water levels, filling and other operating conditions can matter. This calculation cannot diagnose a machine or set a repair tolerance.

No. Head, efficiency, torque and losses are not inputs. Pump and turbine duties require separate energy and equipment assessments.

No. The model contains no shaft stiffness, bearing arrangement, alignment, balance or fatigue calculation.

Pump-design reference

Spaans Babcock: Screw Pump Design Parameters. The manufacturer describes factors affecting real screw-pump performance; the annular-volume model above intentionally uses fewer inputs.

Building or designing a mechanism like this?

Explore the precision-engineered motion control hardware used by mechanical engineers, makers, and product designers.

← Back to Mechanisms Index
Share This Article
Tags: