A Watt-topology six-bar can be synthesized for many motion tasks, including approximate dwell behavior in selected geometries. This calculator counts generic planar mobility and converts an independently entered dwell time into an equivalent input angle at constant speed.
Watt Topology Six-bar Linkage Interactive Calculator
Enter total link count including ground, lower/higher-pair joint counts, constant input RPM and an assumed dwell time. Mobility is a generic criterion; dwell values are time conversions—not a kinematic synthesis or predicted output dwell.
Equation Used
- n includes the fixed ground link.
- j1 counts one-DOF lower pairs and j2 counts higher pairs under the generic planar criterion.
- Input speed is constant.
- Dwell time is independently entered and not derived from linkage geometry.
- The numeric count does not evaluate special constraints, redundant joints, custom assembly, singularities, path, forces, clearances or dynamics.
Six-Bar Count and Dwell-Time Context
A NASA kinematics reference identifies the Gruebler-Kutzbach mobility criterion. Another NASA reference notes that the Kutzbach equation can fail for special planar devices. U.S. Patent 5,297,057 describes dwell synthesis as an actual linkage-design problem—not a time-only conversion.
What This Calculator Represents
The tool applies a generic planar count and converts an entered dwell time to fractions of a constant-speed input cycle.
Mobility and Time-Conversion Calculation
T=60000/N ms
theta_d=360t_d/T
share=100t_d/T
Dwell is entered, not synthesized.
Worked Calculation
For six links, seven lower pairs and no higher pairs, the generic count is one DOF. At 100 rpm the cycle is 600 ms; an entered 80 ms interval corresponds to 48 degrees or 13.3% of that cycle.
Assumptions and Limits
- Calculated: generic mobility count and constant-speed time conversions.
- Illustrated: a fixed illustrative six-bar with two closed loops. Its dimensions are independent of the entered counts and dwell time.
- Not calculated: custom linkage synthesis, actual dwell, path accuracy, singularities, special constraints, forces or dynamics.
Frequently Asked Questions
Does M=1 prove the mechanism assembles?
No.
Can the mobility criterion fail?
Yes, for special or redundant constraints.
Is dwell predicted?
No; time is entered.
What if dwell share exceeds 100%?
The entered time exceeds one entered-speed cycle.
Does the tool identify Watt topology from counts?
No. The animation shows a fixed Watt I example regardless of the entered counts. The count calculation alone cannot distinguish linkage topologies.
Can this synthesize a six-bar?
No.
References
Building or designing a mechanism like this?
Explore the precision-engineered motion control hardware used by mechanical engineers, makers, and product designers.