This page now separates a connected qualitative Bourdon-gauge topology from a declared linear dial mapping and a full-span accuracy-class calculation. It does not model tube deformation, perform calibration or establish instrument suitability or safety.
Declared Bourdon-Gauge Indication Explorer
Enter declared pressure, zero-to-full-scale range, accuracy class and pointer sweep. The connected view shows pressure connection, Bourdon tube, link, sector, pinion and pointer while the worksheet reports only the declared dial mapping and span-based class limit.
Equation Used
- The declared scale runs from zero to full scale FS.
- Pointer mapping is declared linear over sweep S and clamped to the visible scale.
- Accuracy class C is treated as a uniform percent-of-span limit only for this ledger.
- The indicated interval is clipped to the declared zero-to-full-scale range.
- The animation is a prescribed qualitative Bourdon-tip and movement chain; it does not solve tube elasticity or calibrate the linkage.
- Pressure element material and geometry, hysteresis, friction, backlash, temperature, pulsation, vibration, overpressure, media compatibility, fatigue, installation, calibration state, uncertainty, selection, maintenance and safety are excluded.
Removes invented universal Bourdon-tip travel while retaining declared linear dial mapping and manufacturer-supported percent-of-span class arithmetic.
A Bourdon element drives a pointer movement
Manufacturer documentation identifies the pressure connection, Bourdon tube, movement, dial and pointer as gauge components. Pressure-dependent tube-tip motion is transmitted through a linkage and geared movement to the pointer.
The animation keeps those components visibly connected but prescribes their display motion; it does not solve the tube or calibrate the movement.
Use this page only to audit declared indication arithmetic
The worksheet checks a declared zero-to-full-scale linear pointer mapping and converts a declared uniform percent-of-span class into an absolute pressure limit.
It cannot select, calibrate, certify or diagnose a pressure gauge, and it cannot determine whether an instrument is suitable or safe for a process.
Keep dial mapping separate from calibration
The class convention must come from the instrument specification. Real error can vary across the scale and with reference conditions.
A transparent declared-scale example
For P=5.00 bar on a 0–10.00 bar declared scale with a 270-degree sweep, the pointer mapping is 135.0 degrees. A declared class 1.60 percent of span gives an arithmetic limit of ±0.160 bar and a clipped indicated interval from 4.840 to 5.160 bar.
This is not a calibration certificate or uncertainty statement.
Accuracy class is not the whole measurement result
Real indication depends on the applicable standard and grade, gauge size, scale region, reference temperature, hysteresis, friction, backlash, repeatability, vibration, pulsation, mounting, media, overpressure history, condition and calibration.
The former universal 4–8 mm tip-travel claim, scaled tip displacement, broad operating limits, named application claims, failure diagnoses and maintenance instructions are removed because they were not established for one documented gauge.
Pressure-gauge ledger questions
Is the pointer always perfectly linear?
No. Linearity here is a declared mapping, not a physical model.
Is the class limit a calibration result?
No.
Does the animation predict Bourdon-tip travel?
No. Its motion is qualitative and prescribed.
Can this select a safety-critical gauge?
No.
Pressure-gauge references
- WIKA model 213.40: Bourdon-gauge construction, ranges and EN 837-1 accuracy classes.
- WIKA model 111.25CT: percent-of-span accuracy and documented gauge components.
- Ashcroft 8008A datasheet: EN 837-1 percent-of-span accuracy specifications.
- Ashcroft pressure-gauge manual: 270-degree span example and separate zero, span, linearity and friction calibration checks.
Building or designing a mechanism like this?
Explore the precision-engineered motion control hardware used by mechanical engineers, makers, and product designers.