Otis 1861 Hoisting Safety Catch: Hooked Rack-and-Pawl Principle

← Back to Engineering Library

Otis’s 1861 hoisting catch uses a pawl on each side of the platform to engage two fixed racks when lifting-rope tension is lost. Explore the release sequence and count equally spaced rack positions from an entered span and pitch. The calculation does not predict stopping distance, force or load capacity.

Twin-Rack Position Calculator

Enter a declared rack span and uniform pitch. The worksheet counts complete pitch intervals and station locations on each of the two racks; it does not design or rate an elevator safety device.

0°

Full pitch intervals
--
Stations per rack
--
Stations across two racks
--
Unused end remainder
--

Equation Used

n=floor(L/p); stations/rack=n+1; paired stations=2(n+1); remainder=L-np
The count assumes a station at zero and at every full pitch not exceeding the declared span. The 1861 patent does not prescribe these entered dimensions.
  • L and p are nonnegative declared layout dimensions and p is greater than zero.
  • Two racks are counted because the patented catch places one rack on each fixed upright.
  • Station count is arithmetic only; tooth shape, pawl geometry and engagement dynamics are not inferred.
  • Loads, materials, tolerances, spring forces, rope behavior, impact, deceleration, stopping distance, inspection, maintenance, fabrication and code compliance are excluded.

The animation illustrates the paired pawls and rope-operated levers. Rack span and pitch determine the numerical position counts; the drawing uses a fixed illustrative size and spacing.

Rope tension holds the catch; rope failure releases both pawls

US Patent 31,128 describes two fixed uprights, each carrying an inward-facing rack with upward-inclined hooked teeth. The platform carries a bent lever on each side. Their inner ends overlap at an eye on a vertical bar, and the lifting rope attaches to the upper end of that bar.

During lifting, rope tension acts through the bar and levers. If the rope breaks, the patent says springs on the bar and pawls immediately throw the two pawls into the fixed racks. The animation shows that qualitative connected sequence without simulating a fall.

A historic hoisting-platform catch, not modern elevator guidance

Otis patented this arrangement in 1861 as an improvement intended to sustain the platform and load if the lifting rope broke. The hooked rack and pawl shapes direct the platform load so the fixed uprights tend to be drawn together, which the patent presents as resistance to accidental disengagement.

This page explains that historical topology only. Modern elevator safety design, certification, installation, inspection and maintenance require current governing codes and qualified professionals.

Declared rack-station arithmetic

n=floor(L/p); stations/rack=n+1; paired stations=2(n+1); remainder=L-np

L is a declared span and p is a declared uniform pitch. A station is counted at zero and after every complete pitch interval. No value is taken from the patent or used to infer engagement or safety.

Declared layout example

For L=2000 mm and p=40 mm, there are 50 full intervals, 51 stations per rack, 102 stations across the two racks and 0.0 mm unused remainder.

Those counts do not specify tooth geometry, stopping distance, allowable load or a buildable safety device.

Limits of the rack-position calculation

The historical patent describes the connected parts and how loss of rope tension releases the pawls. Counting rack positions cannot determine how quickly they engage, how far a platform falls or the forces produced during arrest.

The animation is a connected explanatory schematic. It deliberately keeps the platform in place while the rope state, vertical bar, levers and pawls change; it does not depict actual descent, impact or deceleration.

Otis safety-catch questions

Does the calculator predict stopping distance?

No.

Why are there two racks?

The 1861 patent places one inward-facing rack on each fixed upright and a pawl on each side of the platform.

What releases the pawls?

Loss of lifting-rope tension allows the spring-biased bar, levers and pawls to move toward engagement.

Does the animation prove engagement reliability?

No.

Can this page be used to design, inspect or certify an elevator?

No.