A geared continuous hinge joins a door and frame with two meshing geared leaves retained by a cap along the hinge. Bearings support the door load. Use this calculator to compare the static moment produced by door weight and its average per inch of hinge length. These quantities describe a simplified load comparison; they do not select a hinge or predict door sag.
Using a linear actuator with Geared Continuous Hinge Mechanism
For actuator sizing, treat geared continuous hinge mechanism as a geometry problem first and a product-selection problem second. The actuator must produce enough push or pull force at the least favorable arm angle, not only at the easiest part of the motion.
With leverage, force is traded against travel. A bracket change that improves force can also increase required stroke, slow the output motion, or move the actuator into a poor mounting angle.
If extra force is added as a margin, confirm that the frame, hinge, pins, and brackets can take the load. A stronger actuator can protect the motor from stalling while quietly moving the failure point into the structure.
- Calculate actuator force at the worst bracket angle, not just at mid-stroke.
- Check stroke, retracted length, and extended length against the mechanism envelope.
- Confirm the structure can accept the higher loads created by a stronger actuator.
For a FIRGELLI actuator application, run the FIRGELLI actuator force calculator, then compare available stroke, force, and mounting envelope in the FIRGELLI linear actuator range. If the goal is to replace an existing unit, use the linear actuator replacement finder before assuming the new actuator is a direct fit.
Geared Continuous Hinge Interactive Calculator
Compare static door-weight moment and its average per inch of hinge length. The comparison value is hypothetical unless independently established on this same basis.
Equation Used
Door weight times half-width gives the static sagging moment, which is divided by hinge length for an average. The comparison does not predict gear stress, opening torque or allowable door weight.
- Door center of gravity is at half the door width.
- Moment divided by length is an average; local bearing and fastener loads are not calculated.
- Static bending moment only; impact, abuse, and frame misalignment are not included.
- Compare only values on the same lb-in/in basis; this is not a product-selection rating.
How a geared continuous hinge works
The geared edges of the two leaves move together as the door opens. A full-length cap retains the assembly, and bearings carry vertical load. This differs from a pin-and-barrel hinge, which rotates around a central pin.
The hinge extends along the door edge and provides many attachment points. Actual forces depend on the bearings, fasteners, door, frame and installation. Dividing the door-weight moment by hinge length does not calculate the load on an individual bearing or fastener.
Key parts
- Door leaf: attaches to the door and carries one geared edge.
- Frame leaf: attaches to the frame and carries the mating edge.
- Gear cap: retains the geared assembly along its length.
- Bearings: support vertical load while allowing motion.
- Fasteners: transfer forces between the hinge, door and frame.
The left view shows the vertical hinge and downward door load. The enlarged top section shows the door leaf rolling around the fixed frame leaf through an illustrative 0–180° opening, while the retaining cap turns through half that angle. The load calculation is independent of this opening sequence. Tooth profiles, retaining grooves and clearances are simplified; the top section does not show vertical bearings or predict stress or sag.
Choosing a hinge for a door
Geared continuous hinges are used on commercial and institutional doors where door weight, frequency of use and mounting conditions matter. Select the mounting style for the actual door and frame: concealed, surface and mixed mounting arrangements require different clearances and attachment details.
Manufacturer selection information takes priority over this simplified calculation. For example, SELECT specifies geared-hinge duty using door weight and frequency of use, with conditions on door width and construction. It does not give the universal moment-per-inch ratings assumed by this calculator’s comparison input.
Static door-weight moment
For a uniform door, assume its centre of gravity is halfway across its width: d = b/2. The weight produces a sagging moment of magnitude M = Wd about a horizontal axis through the hinge support. This is not opening torque about the vertical hinge axis.
Average moment per unit hinge length = M/L = Wb/(2L)
W is door weight in pounds-force, b is door width in inches, and L is hinge length in inches. M is in lb·in and M/L is in lb·in/in. The latter is an average comparison quantity, not an analysis of bearing or gear-tooth stress.
The entered comparison value R gives a numerical reserve R − M/L and utilization 100 × (M/L)/R. Use a value on this exact basis only; a manufacturer’s allowable door weight in pounds cannot be entered as though it were a moment-per-inch rating. A positive reserve does not establish that a hinge is suitable.
Example: a 220 lb, 36 inch door
With W = 220 lb, b = 36 in and L = 83 in, the assumed centre-of-gravity distance is 18 in. Total static moment is 220 × 18 = 3,960 lb·in. Dividing by 83 in gives 47.71 lb·in/in.
If you enter a hypothetical comparison value of 60 lb·in/in, the numerical reserve is 12.29 lb·in/in and utilization is 79.52%. This value is not a rating for a SELECT, Pemko, ABH or other commercial hinge.
Changing only the weight to 100 lb gives 21.69 lb·in/in; changing it to 450 lb gives 97.59 lb·in/in. A longer hinge reduces this average, but does not by itself establish a higher allowable door weight. Check the exact hinge’s published application limits and installation requirements.
Comparing hinge arrangements
| Arrangement | Main distinction | Selection information needed |
|---|---|---|
| Geared continuous hinge | Meshing leaves retained along the door edge | Exact model, door weight and width, use frequency, bearings, attachment and clearances |
| Pin-and-barrel continuous hinge | Interleaved knuckles along a continuous pin | Material, dimensions, bearings, fasteners and published application limits |
| Individual butt hinges | Separate hinges spaced along the door edge | Hinge size, quantity, spacing, bearing type, frame reinforcement and door construction |
Cycle life, fire rating, security provisions and electrical transfer are properties of a tested product and installation. They cannot be inferred from hinge type or the average moment alone.
Frequently asked questions
Does the calculator select a hinge for my door?
No. It calculates a static weight moment and divides it by hinge length. Select the exact product using the manufacturer’s door-weight, width, frequency and mounting conditions.
What should I enter for the comparison value?
Only a reference expressed on the same moment-per-length basis, in lb·in/in. The default 60 is a hypothetical comparison value, not a published product rating. Do not substitute a door-weight limit in pounds.
Is Total Moment the torque needed to swing the door?
No. It is the sagging moment from gravity acting at the assumed centre of gravity. Opening torque depends on the closer, seals, hinge resistance and other forces.
Does increasing hinge length guarantee less sag?
No. It reduces the calculated average M/L. Actual sag also depends on door and frame stiffness, bearings, attachment and installation.
Can a geared hinge be cut to length?
Some models allow field cutting under their installation instructions. Others have different restrictions. Confirm the exact model, cut location, bearing arrangements and handedness rather than assuming that all cutting voids the warranty.
Do all geared hinges need the same lubrication?
No. Follow the exact product’s instructions. SELECT describes a permanent dry-graphite coating; this does not establish a universal lubricant for other products.
How are power-transfer and fire-door versions selected?
Use the manufacturer’s specific configuration and approvals for the door assembly. This calculator does not check electrical transfer, fire rating or security performance.
Manufacturer references
- SELECT architectural specifications: duty, door and mounting conditions.
- SELECT frequently asked questions: bearing arrangement, mounting styles and product care.
- SELECT product catalogue: model-specific details and installation references.
Continue exploring engineering
Find another tool, explore an animated mechanism, or browse resources by subject.
Building or designing a mechanism like this?
Explore the precision-engineered motion control hardware used by mechanical engineers, makers, and product designers.