A drainage wheel is an externally powered wheel that moves water from a low channel to a higher one. Inclined paddles sweep through a close-fitting curved shield beneath the wheel. The shield and channel walls guide the lifted water toward the discharge. The wheel consumes shaft power; it is not being driven by the water it lifts.
Drainage Wheel Interactive Calculator
Enter target water flow, lift head, wheel speed, an assumed efficiency and wheel diameter. Estimate shaft power and running torque while inspecting the water-lifting route.
Equation Used
- Fresh-water density 1000 kg/m³ and gravitational acceleration 9.81 m/s².
- Head is the difference between inlet and outlet free-surface levels.
- Steady target flow and entered overall wheel efficiency.
- No capacity, transient-load or structural sizing model.
- Paddles, hub, width and clearance are schematic; diameter and head set the illustrated scale.
Fresh water; entered flow is a target, and efficiency an assumption. No hydraulic capacity or component rating is predicted.
Paddles work inside a curved current shield
Hiscox’s movement 479 shows a large power-driven wheel with broad, backward-inclined blades and a curved passage beneath it. This side-section animation follows that arrangement: the low inlet is on the left and the higher channel on the right, with counterclockwise wheel rotation carrying water beneath the shaft.
The blue route and moving dots indicate flow direction. They do not simulate fluid pressure, leakage, free-surface motion or blade-pocket filling. The wheel width extends into the page; the number and thickness of the illustrated paddles are schematic.
Wheel diameter and water-level difference control the relative levels in the drawing. The channel clearance is enlarged for visibility. It is not a specified construction clearance.
Low-head water lifting
The historical reference describes drainage of fens and lowlands and associates this wheel form with lifts approaching half its diameter. That description explains the scale of the arrangement; it does not certify the flow or efficiency of a proposed wheel.
Use the calculator to estimate the energy demand for an entered flow and head, then examine how wheel speed changes the required average running torque. Hydraulic capacity still depends on width, blade form, clearances, inlet conditions and a verified performance model or measurement.
Flow, head, power and torque
For fresh water, take density ρ=1000 kg/m³ and g=9.81 m/s². Hydraulic power is Pwater=ρgQH watts. If the assumed overall wheel efficiency is η, the required shaft power is Pshaft=Pwater/η.
At n rpm, angular speed is ω=2πn/60 radians per second. Average running torque is T=Pshaft/ω. The displayed power is in kW and torque in kN·m. Paddle-tip speed is u=πDn/60 m/s.
Specific shaft energy is ρgH/(3600η) Wh per cubic metre. Target delivery per revolution is 60000Q/n litres. This delivery number is a requirement implied by the entered flow and rpm, not a prediction from the drawn blades.
At zero rpm with positive target flow, the calculator cannot give a finite running torque or delivery per revolution. The required continuous-service power remains visible as a design demand, while the wheel is marked stopped. At zero flow, the hydraulic and calculated useful-lifting power are zero; this excludes no-load mechanical losses.
A 2 m³/s target at a 1 m lift
With Q=2 m³/s, H=1 m and assumed efficiency 68%, water power is 19.62 kW and required shaft power is about 28.85 kW. At 6 rpm, average running torque is about 45.92 kN·m.
A 6 m wheel at 6 rpm has a paddle-tip speed of 1.885 m/s. The entered delivery target corresponds to 20000 litres per revolution. These are calculated requirements; they do not establish that a particular 6 m wheel has sufficient width or effective capacity.
Doubling rpm halves the torque required for the same shaft power and halves the target volume per revolution. Doubling diameter doubles tip speed at the same rpm, while leaving the energy calculation unchanged if the assumed efficiency is held fixed.
Keep energy estimates separate from wheel capacity
Overall efficiency is an input to the estimate. It is not automatically derived from head, blade speed or diameter. Use measured performance or an appropriate hydraulic design analysis to select it.
The model does not size shafts, bearings, blades, gearing or foundations. Starting torque, fluctuating blade loads, debris, leakage and structural deflection are outside the calculation.
The sketch follows a historical scoop-wheel form. Its schematic gaps, 24 blades, hub and channels are not manufacturing dimensions. The selected diameter and head range keeps the shown lift no greater than half the wheel diameter, without claiming that every combination is suitable.
Drainage-wheel questions
Is the inlet flow driving the wheel?
No. An external drive supplies the energy needed to lift water to the higher channel.
Why does diameter change tip speed but not shaft power?
For fixed flow, head and assumed efficiency, energy demand is unchanged. Diameter changes peripheral speed; its real effect on efficiency is not predicted here.
Does twice the rpm mean twice the flow?
Not from this calculator. Flow is a target you enter. Actual delivery needs a hydraulic capacity model or test.
What happens at zero rpm?
The wheel and flow markers stop. A positive target flow cannot be sustained; finite running torque is not reported.
Are the channel gaps to scale?
No. Clearance is enlarged to make the mechanism visible, and it is not a construction recommendation.
References
Gardner D. Hiscox, Mechanical Movements, Powers and Devices, movement 479, printed page 134, shows the externally driven inclined-paddle wheel and current shield. The calculator applies the gravitational energy rate ρgQH and rotational power relation P=Tω stated above.