Wheeler Vertical Tube Boiler Mechanism: How It Works, Parts, Diagram, and Steam Calculator

← Back to Engineering Library

Compare the outside surface area of a vertical-tube bundle and the heat input from an assumed uniform heat flux. The evaporation estimate uses an approximate latent heat; it does not predict actual boiler output.

Wheeler Vertical Tube Boiler Interactive Calculator

Enter tube count, outside diameter, active length, assumed uniform heat flux and gauge pressure. Latent heat is estimated with the displayed approximate equation; boiler safety, circulation and ratings are not calculated.

0°

Outside lateral tube area
--
Entered-flux area product
--
Ideal latent-only quotient
--
Bounded calculator approximation
--

Equation Used

A=N pi D L; duty=Aq; pabs=pg+1.01325; hfg=clip(2257-103 ln(pabs),1850,2150); ideal evaporation=3600 duty/hfg.
Only the outside cylindrical tube surface is counted. The logarithmic expression estimates latent heat within fixed bounds; it does not replace steam-table data.
  • Identical tubes use full entered length as active outside area.
  • Heat flux is uniform and entered independently.
  • Gauge pressure is converted to approximate absolute bar.
  • Latent heat follows the displayed bounded approximation.
  • Circulation, water inventory, sensible heating, blowdown, combustion, losses, stress and safety are omitted.
Same mechanism and inputs as the interactive calculator.

Vertical-Tube Area and Duty Screen

NIST Chemistry WebBook water data provides thermophysical context. For the calculation shown here, latent heat comes from the displayed approximate equation rather than the NIST tables.

What This Calculator Represents

An ideal outside-area and latent-only evaporation comparison.

Area, Duty and Quotient

A=NpiDL
Qdot=Aq
hfg=clip(2257-103ln(pg+1.01325),1850,2150)
mdot=3600Qdot/hfg

Worked Scenario

At 60 tubes, 57.5 mm OD and 1.5 m length, area is about 16.26 m2. At 10.4 kW/m2, duty is about 169 kW; the approximation then gives an ideal latent-only evaporation quotient.

Assumptions and Limits

  • Calculated: lateral area, entered-flux product and approximation quotient.
  • Not calculated: real steam tables, circulation, efficiency, combustion, stress, controls or safety.

Frequently Asked Questions

Is latent heat from a steam table?

No.

Is evaporation guaranteed?

No.

Is sensible heating included?

No.

Is heat flux predicted?

No.

Are tube ends counted?

No.

Can this rate a boiler?

No.