A synchronous electric clock drives its hands with a motor whose speed follows the supply frequency. Reduction gearing converts that rotation to the required hand speeds. This calculator links the clock hands to the entered frequency, motor pole count and reduction ratio, and distinguishes frequency drift from a gear-ratio error.
Electric Time Clock Interactive Calculator
Link a synchronous motor to a real clock dial. Compare frequency-only drift with the actual hand-rate error caused by frequency, pole count and gearing.
Equation Used
- Constant actual frequency and synchronized motor.
- Entered ratio drives the second-hand shaft.
- Minute and hour hands use subsequent ideal 60:1 and 12:1 reductions.
- No torque, starting, outage, backlash or grid-history model.
Assumes locked synchronous operation. Total ratio is entered, not a gear-train design.
A motor-driven clock dial
The synchronous motor turns at a speed determined by electrical frequency and pole count, provided it remains synchronized. A reduction train drives the clock movement. The rear diagram represents the motor, enclosed reduction mechanism and output spindle; the entered ratio represents the reduction of the complete train.
The green hand is treated as the second hand and makes one revolution per indicated minute. Further ideal reductions drive the minute hand at one-sixtieth of its speed and the hour hand at one-twelfth of the minute-hand speed. All three begin at 10:10:00 and move from the same calculated time advance.
The rear motor’s pole layout is schematic and its high-speed rotation is not animated. The dial uses a stated time scale; at extreme output speeds playback slows enough to keep the hands visible.
Check frequency and gearing separately
Enter actual supply frequency, an even motor pole count, total reduction from the motor to the second-hand shaft and nominal design frequency. Together these inputs distinguish frequency drift from a gearing error.
The nominal 1 rpm reduction tells you what total ratio would give a correct second-hand rate at the design frequency. Changing the entered ratio away from that value changes actual dial rate even when actual and nominal frequency are identical.
Frequency-only drift answers a different question: how much a correctly calibrated synchronous clock gains or loses because its supply frequency differs from its design frequency. It intentionally does not depend on an arbitrary entered gear ratio.
Synchronous speed and indicated time
For supply frequency f in hertz and P motor poles, synchronous rotor speed is n=120f/P rpm. With total reduction R, second-hand shaft speed is nh=n/R rpm and angular speed is ω=2πnh/60 radians per second.
The reduction required for a 1 rpm second-hand shaft at nominal frequency f₀ is R₀=120f₀/P. A calibrated clock’s frequency-only drift is 60(f/f₀−1) seconds per real minute.
For the actual entered pole count and gearing, the dial indicates 60nh seconds during one real minute. Its actual rate error is therefore 60(nh−1) s/min. Positive values mean gaining time, negative values losing time.
The minute and hour hand angles come from the same indicated seconds, divided by 3600 and 43200 seconds per revolution respectively.
Default synchronous clock
At 60 Hz with 16 poles, the synchronous rotor turns at 450 rpm. A 450:1 reduction gives a 1 rpm second-hand shaft and angular speed approximately 0.10472 rad/s. At a nominal 60 Hz, both drift outputs are zero.
If actual frequency becomes 59.5 Hz while the other defaults remain unchanged, the second-hand shaft turns at approximately 0.991667 rpm. The clock loses 0.5 seconds per real minute.
If instead frequency remains 60 Hz and the reduction is doubled to 900:1, frequency-only drift stays zero but the actual dial loses 30 seconds per real minute. The separate actual dial-rate result identifies that gearing error.
Assumptions and omitted effects
The motor is assumed synchronized, with constant actual frequency during the observation. Starting behavior, load torque, magnetic design, outages, backlash and loss of synchronism are not modeled.
A constant frequency error is different from a changing electrical-grid history. Predicting accumulated real-world clock error requires integrating the actual frequency record and accounting for interruptions or corrections. This page does not promise long-term grid accuracy.
The entered total reduction is a kinematic ratio, not a synthesized gear train. Pole geometry in the rear schematic identifies the pole-count input without specifying windings or a particular commercial motor.
Electric clock questions
Why can frequency drift be zero while the clock runs incorrectly?
Actual and nominal frequencies may match while the chosen motor poles and gear ratio produce the wrong second-hand speed. The actual dial-rate result exposes that difference.
Why do the hands sometimes move much faster than a real clock?
Playback has a stated display time scale, and the entered reduction may also be far from a correct clock ratio. Numerical results remain in physical units.
Does this require a particular motor brand?
No. It is an ideal synchronous-speed model, not a replica or winding design for a named motor.
What does one cycle-slider revolution represent?
Sixty physical seconds. Autoplay can continue through later minutes, with all three hands advancing together.
References
- Oriental Motor, AC Motor Introduction — synchronous speed as 120 times frequency divided by pole count.
- Henry E. Warren, US1502493A: Time-indicating apparatus — synchronous motor and gearing used for time indication and comparison.
- NIST, Time and Frequency Users’ Manual — electrical-frequency timing and synchronous clocks.
Continue exploring engineering
Find another tool, explore an animated mechanism, or browse resources by subject.