A compound locomotive passes steam from a high-pressure cylinder into a lower-pressure stage before final exhaust. This page compares the bores of a generic two-cylinder arrangement at equal stroke. The cutaway shows how piston rods, guided crossheads and connecting rods drive the wheels.
Compound Locomotive Cylinders Interactive Calculator
Compare HP and LP bores at equal stroke, select a target volume ratio and see the corresponding LP bore. The two pressure inputs also give full-face static force comparisons. The unfolded animation shows connected piston-to-wheel motion on both sides.
Equation Used
- One HP and one LP cylinder with equal illustrative strokes.
- Opposite sides are unfolded into separate rows and viewed in the same longitudinal direction, with crankpins 90 degrees apart.
- Piston rods remain axial, crossheads stay guided, and connecting rods keep constant length.
- Pressures are psig; final exhaust is assumed atmospheric. Full-face static forces omit rod areas and valve events.
- Stroke, connecting-rod lengths, wheel diameter and playback speed are illustrative, not locomotive design inputs.
Compare cylinder bore ratios and full-face forces at the entered constant pressures. Predicting steam expansion, power or tractive effort also requires pressure histories and valve timing.
What the unfolded cutaway shows
The two rows represent opposite sides of a two-cylinder locomotive, unfolded and viewed in the same longitudinal direction. Each piston has a straight rod through its cylinder gland into a guided crosshead. A connecting rod links that crosshead to a driving-wheel crankpin. The two crankpins are a quarter turn apart.
Both cylinder bores use the same drawing scale and both pistons have the same illustrative stroke. The dashed outline around the LP cylinder shows the target bore. It is a comparison outline, not another moving cylinder.
The flow strip identifies the sequence boiler, HP stage, receiver, LP stage and exhaust. It does not show the internal valve passages or timed admission and exhaust events. Henderson’s two-cylinder compound locomotive patent supplies the HP/LP layout and stage-routing reference; the animation is a generic interpretation, not a replica of that patented valve system.
Why compare the cylinder sizes?
At equal stroke, cylinder swept volume is proportional to piston area. Comparing bores therefore gives a direct geometric comparison of the two stages. A selected target ratio can be converted into a target LP bore.
The target is a user choice, not an automatically optimal steam-engine design. Performance also depends on valve events, pressure histories, temperatures, clearance volumes and losses. Those quantities are outside this calculator.
Bore ratio and pressure-area comparisons
For equal strokes, VLP/VHP = ALP/AHP = (DLP/DHP)². A target ratio R therefore needs DLP,target = DHP√R. The bore difference is 100(DLP−DLP,target)/DLP,target.
With all pressures expressed as gauge pressure, the full-face static comparisons are FHP = (πDHP²/4)(Pboiler−Preceiver) and FLP = (πDLP²/4)Preceiver, assuming atmospheric final exhaust.
These are pressure-difference times area calculations. They do not integrate the pressure through a stroke or account for the piston rod area. They must not be read as average cylinder force, drawbar pull or engine power. A pressure ratio is a different quantity and would require absolute pressures.
Example: 14-inch HP and 22-inch LP bores
The equal-stroke volume ratio is 22²/14² = 2.469:1. For a target ratio of 2.25:1, the target LP bore is 14√2.25 = 21 inches. The entered 22-inch bore is 4.76% larger than that target.
At 220 psig boiler and 50 psig receiver pressure, the HP comparison uses a 170 psi difference, giving about 26,169 lbf on its full face. The LP comparison uses 50 psi above atmospheric exhaust and gives about 19,007 lbf. These simplified static figures do not describe a complete working cycle.
What the geometry cannot decide
A larger LP bore increases its swept volume and its full-face force at a specified pressure difference. It also changes the physical cylinder. The calculator makes no claim about fuel savings, balancing, starting performance or structural suitability.
Entering an LP bore no larger than the HP bore is permitted for comparison, but the drawing flags that relationship. The selected target does not silently replace the actual bore.
Questions about the cylinder comparison
Why does bore ratio use a square?
Piston area is proportional to diameter squared. Equal stroke makes the swept-volume ratio equal to the area ratio.
Do the pressure sliders change the bore ratio?
No. They change the static force comparisons. Bore ratio remains a geometric result.
Does the animation show two cylinders stacked vertically?
No. The opposite sides are unfolded into two separate rows so both connections are visible.
Does the force result predict tractive effort?
No. The calculation omits pressure histories, valve events, rod areas and the conversion from wheel torque to rail force.
Is the green outline another cylinder?
No. It is the target LP bore, shown alongside the entered actual bore.
References
- G. R. Henderson, US631164A, Two-cylinder compound locomotive, Figure 1 and the description of HP/LP cylinders and compound steam routing.
- Railtown 1897 State Historic Park: Crankin’ out Crankpins, quartering the crankpins on opposite wheels.
The animation uses generic proportions and does not reproduce the patented intercepting or reducing valves.
Building or designing a mechanism like this?
Explore the precision-engineered motion control hardware used by mechanical engineers, makers, and product designers.