This balance-pump example transfers liquid from the fuller of two reservoirs to the emptier one. Each liter moved reduces the volume difference by two liters: one leaves the source and one enters the destination. The calculator uses a constant delivered flow to estimate transfer volume and time, with an optional remaining difference called a deadband.
Balance Pump Interactive Calculator
Vary tank capacity, imbalance, pump flow, and deadband to see transfer volume and equalisation time for a reversible balance pump.
Equation Used
The balance pump runs until the measured difference falls inside the controller deadband. The calculator converts percentage imbalance into litres, subtracts the allowed deadband volume, then divides the remaining transfer volume by pump flow.
- Total capacity is the combined capacity of both tanks.
- Pump flow is constant and bidirectional.
- Controller stops when the volume difference reaches the deadband.
- Leakage, sloshing, acceleration time, and overshoot are ignored.
Cross-transfer changes the difference by twice the transferred volume. The tanks have equal areas and no external flows; total capacity is the sum of both tank capacities.
Transferring liquid reduces both sides of the difference
Let the starting volumes be VA and VB, with A fuller. After transferring volume x, they become VA − x and VB + x. Their difference is therefore the initial difference minus 2x. Total liquid volume stays constant when there are no outside flows.
The illustrated controller stops when the remaining volume difference reaches the selected deadband. Replaying the animation starts the same example again; it does not show a continuously replenished process.
Parts in the example
- Two reservoirs: store the liquid.
- Transfer pump and piping: carry liquid between them.
- Measurements and controller: compare the quantities and decide when to stop.
The animation assumes a reversible transfer arrangement. An actual pump, motor, valves and seals must be designed for their operating direction and fluid. Reversing a motor is not a universal way to reverse flow through every pump.
Reservoir balancing as a volume calculation
Tank-to-tank liquid transfer can be useful when a process requires a chosen distribution of liquid. Reversible gear pumps are one available equipment type: MARCO, for example, lists a UP3-R transfer pump with a reversing switch. That does not establish its suitability for the example flow rates, liquids or operating conditions here.
Equal volumes are not the same as equal levels in tanks with different shapes. Nor does equal volume establish equal pressure, temperature or vessel trim. Those tasks require additional geometry, fluid properties and system information.
The calculator does not model hydronic branch balancing, boiler protection or aircraft fuel procedures. It is a closed two-reservoir volume balance with no external inflow or withdrawal.
Volume difference and transfer time
Let C be the combined capacity of both tanks in liters, δ the initial volume difference as a percentage of C, db the deadband percentage of C, and Q the actual delivered transfer flow in L/min.
Initial difference ΔV = Cδ/100. Allowed remaining difference B = Cdb/100. Transfer volume x = max(0, ΔV − B)/2. Time to deadband = x/Q minutes. Time to zero difference = ΔV/(2Q) minutes.
The factor of two is essential for cross-transfer. Removing liquid from one tank to an external drain would be a different problem. Q must already represent delivered flow at the actual duty; no efficiency factor is applied in this calculator.
The model ignores acceleration, changing flow, leakage, sloshing and controller delay. It also does not check absolute starting contents, suction availability or receiving-tank headroom. Capacity and difference alone cannot verify those conditions.
Worked example: a 400-liter difference
Suppose two 5000 L tanks have combined capacity C = 10,000 L. An initial difference of 4% is 400 L, and a 0.5% deadband is 50 L. Required transfer is (400 − 50)/2 = 175 L.
At an actual delivered flow of 100 L/min, time to deadband is 1.75 minutes and time to exact equality is 2 minutes. At 50 L/min, those times are 3.5 and 4 minutes. At 200 L/min, they are 0.875 and 1 minute.
If a separate pump assessment predicts 88 L/min delivered, enter 88: time to deadband is 175/88 = 1.9886 minutes and time to equality is 200/88 = 2.2727 minutes.
When the entered difference is already inside the deadband, required transfer and time to deadband are zero. Time to zero difference still describes the separate hypothetical transfer needed for exact equality. None of these times selects a pump or predicts cavitation, control stability or safe operation.
Different ways to move liquid
| Arrangement | What determines transfer | Not established here |
|---|---|---|
| Controlled cross-transfer | Delivered pump flow and stopping logic. | Pump selection, pressure losses and controller tuning. |
| Passive connection | Pressure or liquid-head difference and resistance. | Equalization time or suitability of the connection. |
| Separate supply and withdrawal | Each reservoir’s external flow balance. | The simple two-for-one difference reduction used here. |
A positive-displacement pump still has pressure, fluid, speed and protection limits. A constant-flow assumption is a simplification, not a guarantee that flow is independent of the system.
Balance-pump calculation questions
Because one tank loses the transferred volume while the other gains it. A 1 L transfer reduces their difference by 2 L.
It is the sum of both tank capacities. The initial difference and deadband percentages both use that combined value.
No. The inputs do not specify absolute contents, so the calculator cannot check whether the source contains enough liquid or the destination has enough free capacity.
Only for suitable matching tank geometry and reference elevations. Different tank shapes require a volume-to-level relationship for each tank.
Enter the delivered flow expected at the actual fluid and pressure conditions. If it changes substantially during transfer, a constant-flow time is only an approximation.
No. Measurement noise, delay, external flows and controller behavior are omitted. There is no universal deadband or cycle duration determined by these inputs.
No. Reversible operation must be supported by the complete pump and drive arrangement. Check the exact manufacturer documentation.
No. Such actions can damage equipment or create hazardous pressure. Follow the equipment-specific service and isolation procedure; no diagnostic operating test is supplied here.
Further reading
- OpenStax, Fluid dynamics and continuity, for conservation of incompressible-fluid volume.
- MARCO, UP3-R reversible transfer pump, a product example rather than a recommendation for the calculation above.
Continue exploring engineering
Find another tool, explore an animated mechanism, or browse resources by subject.
Building or designing a mechanism like this?
Explore the precision-engineered motion control hardware used by mechanical engineers, makers, and product designers.