In an arc-tappet rock-drill valve, shoulders on the reciprocating piston strike a tappet arm, rocking the valve around the tappet center. The animation shows the piston-triggered motion. The adjacent calculator compares an ideal on/off event over a repeating cycle.
Arc Tappet Valve Motion Interactive Calculator
Explore piston-triggered arc-tappet valve action and a separate idealized valve-event timing calculator.
Equation Used
The timing chart assigns either zero or the entered travel H to a selected phase. Open duty is the forward interval from opening to closing angle, including a wrap through zero when needed. Open time is that fraction of the entered cycle period. The chart is separate from the piston-driven contact geometry.
- One ideal timing cycle is counted per entered blow; the historical piston-triggered mechanism has no continuously rotating cam.
- The timing chart uses an instantaneous step between zero and H, not a physical velocity or acceleration law.
- Cycle angles are normalized modulo 360 degrees; identical opening and closing angles give zero duration.
- Pressure, flow, contact forces and piston dynamics are not calculated.
The mechanical animation uses the historical piston-shoulder/tappet arrangement. Entered open and close angles define only the separate ideal timing chart, not a manufactured tappet profile. Instantaneous step travel is an idealization, not achievable physical acceleration.
Piston shoulders switching a rocking valve
Hiscox’s entry 1199 describes the “Sergeant” rock-drill arrangement: the valve moves on a circular path about the tappet center, and shoulders on the piston strike the tappet arm. The piston’s own travel therefore supplies the mechanical trigger for switching the valve.
As one shoulder reaches the arm, contact rocks the tappet and valve. On the opposite stroke, the other shoulder acts from the other side. Between contacts the illustration holds the valve in its previous position. Watch the shoulder-to-arm contact, the pivot and the upper valve sector to follow the sequence.
Main parts
- Reciprocating piston: carries the two triggering shoulders.
- Tappet arm: receives the alternating contacts.
- Pivot: defines the center of the rocking motion.
- Curved valve: moves with the tappet to change the flow connections.
The picture explains the switching sequence, not detailed port overlap or the pressure-driven piston trajectory. The open/close angle controls belong to the separate timing chart; they do not move the physical contact points in the illustrated mechanism.
Historical rock-drill valve gear
The historical example is a rock-drill valve actuated by direct contact with piston shoulders. It illustrates how a reciprocating machine can switch its valve without a separate rotating timing shaft.
This identification does not establish that a named modern drill, hydraulic breaker or stamp mill uses the same arrangement. Modern equipment needs its own parts drawing and valve description.
The animation is useful for following the mechanical trigger, while the numerical chart compares event duration at an entered cycle rate. Neither supplies manufacturing clearances, spring selection, wear limits or repair instructions for a working drill.
An ideal timing interval
Normalize the cycle angle θ, opening angle θo and closing angle θc modulo 360°. Let Δ = (θc − θo + 360°) mod 360°. Open Duty = 100Δ/360 percent, Open Time = (60000/BPM)Δ/360 milliseconds and Blow Rate = BPM/60 hertz.
Ideal valve state is H during a nonzero forward opening interval and zero outside it. For an interval crossing 0°, angles at or beyond opening, or at or before closing, are included. Both boundary angles are included in the instantaneous state test. Identical opening and closing angles give zero duration and a closed state.
H scales the selected state value and illustrated throw; it does not change duty, duration or frequency. Increasing BPM shortens open time but leaves angular duty unchanged. The step chart has no finite rise or fall ramp and cannot predict acceleration, valve float, pressure rise or blow energy.
Worked example: timing and a wrapped interval
Choose opening 60°, closing 240°, H = 6 mm and 1800 BPM. The forward interval is 180°, so Open Duty is 50.0%, the cycle period is 33.3333 ms, Open Time is 16.6667 ms and Blow Rate is 30.0 Hz. At θ = 180° the selected state is 6 mm; at θ = 300° it is zero.
At 1200 BPM, the same angular interval lasts 25 ms and event frequency is 20 Hz. At 2400 BPM, it lasts 12.5 ms and frequency is 40 Hz. Neither rate changes H or proves the physical valve can follow that timing.
For opening 300° and closing 60°, the interval crosses zero and spans 120°. At 1800 BPM it gives 33.3333% duty and 11.1111 ms open time. The state is H at θ = 0° and zero at θ = 180°. Setting both endpoints to 60° gives zero duty and zero open time, rather than a full-cycle opening.
Two ways of describing valve timing
| Description | What it tells you | What else is needed |
|---|---|---|
| Piston-shoulder mechanism | Where contact switches the rocking valve. | Dimensions, ports, pressure and dynamics to predict actual motion. |
| Ideal on/off chart | A chosen phase interval and its duration at constant cycle rate. | A realizable transition law and machine model to predict performance. |
Equal duty does not mean equal admission flow or impact energy. Those depend on the valve openings, fluid conditions and piston work, none of which is calculated here.
Arc-tappet and timing questions
The historical arrangement shown is driven by piston shoulders striking a rocking tappet. Its circular valve motion is around the tappet pivot.
No. They set the separate ideal event chart. The picture’s physical triggering sequence is not synthesized from those angles.
The timing interval wraps through zero. Opening at 300° and closing at 60° gives a 120° interval.
The implemented timing convention gives identical endpoints zero duration. It does not interpret them as a full-cycle opening.
That cannot be inferred from event frequency alone. The calculator has no pressure, flow, piston mass or impact model.
No. It contains no manufacturing or wear model. Those values require the specific machine’s engineering documentation.
H is the nonzero state amplitude. Timing is determined independently by the angular interval and BPM.
No. A physical valve has a finite transition. The step chart compares timing only and cannot provide velocity or acceleration limits.
Historical reference
Gardner D. Hiscox, Mechanical Movements, Powers, Devices and Appliances, entry 1199, identifies the Sergeant arc-tappet rock-drill valve and describes the piston shoulders acting on its tappet arm.
Building or designing a mechanism like this?