This partial calculator evaluates ideal air power from entered volumetric flow and pressure rise, converts the two entered quantities to SI units, and calculates selected circular tip travel per minute. It does not predict shaft or engine power, efficiency, an operating point, ventilation performance, structural loads or safety.
Steam-driven Ventilating Fan - Selected Air-Power/Conversion Ledger
Explore selected ideal air power, authoritative unit conversions and circular tip travel.
Equation Used
- Flow, conventional water-column pressure, rotor diameter and rotational speed are entered values.
- Q times pressure divided by 6356 is ideal air power, not shaft or engine power.
- One cubic foot per minute is converted using 4.719474e-4 cubic metre per second.
- One conventional inch of water is converted using 249.08891 pascals.
- Tip travel is selected circumference times revolutions per minute; fan, drive, system and safety performance are excluded.
The secondary figure is an abstract arithmetic ledger, not a ventilating-fan or steam-engine design.
Selected air-power and conversion ledger
The Department of Energy fan-power relationship is evaluated with unit efficiency, so Q times pressure divided by 6356 is air power delivered to the airstream, not shaft power. NIST conversion factors convert the selected flow and conventional water-column pressure. Circumference pi D times selected revolutions per minute gives geometric tip travel per minute.
What the calculator determines
Use it to inspect the four stated arithmetic relationships for entered values. It cannot select, size or validate a fan, steam engine, drive, duct or mine-ventilation system.
Selected relationships
P_air=Q Delta p/6356; Delta p_Pa=249.08891 Delta p_inH2O; Q_SI=0.0004719474 Q_cfm; v_tip=pi D N.
Selected-input example
At 200000 cfm, 2 in conventional water column, 20 ft selected rotor diameter and 60 rpm, ideal air power is about 62.933 hp, converted pressure is about 498.178 Pa, converted flow is about 94.389 m3/s and selected geometric tip travel is about 3769.911 ft/min.
Not a fan or engine performance model
Fan efficiency, drive efficiency, shaft power, engine power, fan curve, system curve, density correction, compressibility, blade or diffuser geometry, actual rotor speed under load, stresses, guards, controls and ventilation safety are excluded.
Questions
Is air power the required shaft power?
No. The DOE equation divides by fan efficiency to obtain fan input power; setting efficiency to one leaves ideal power delivered to the air.
Does the selected flow occur at the selected pressure?
Not necessarily. An actual operating point requires validated fan and system curves.
Is tip travel a blade-stress limit?
No. It is only circumference times selected revolutions per minute.
Authoritative references
- U.S. Department of Energy Nuclear Air Cleaning Handbook, Chapter 2 — gives fan horsepower as Q times pressure divided by 6356 times fan efficiency.
- U.S. Department of Energy Fan System Information Card — gives the fan-power relationship and fan affinity-law context.
- NIST Guide to the SI, Appendix B.9 — gives the cubic-foot-per-minute to cubic-metre-per-second conversion.
- NIST Guide to the SI, Appendix B.8 — gives conventional water-column pressure and foot-per-minute conversion factors.
References & Further Reading
- Wikipedia contributors. Mine ventilation. Wikipedia
Continue exploring engineering
Find another tool, explore an animated mechanism, or browse resources by subject.
Building or designing a mechanism like this?
Explore the precision-engineered motion control hardware used by mechanical engineers, makers, and product designers.