Steam-driven Ventilating Fan Mechanism: How Guibal Colliery Fans Work, Parts, Diagram and Uses

← Back to Engineering Library

This partial calculator evaluates ideal air power from entered volumetric flow and pressure rise, converts the two entered quantities to SI units, and calculates selected circular tip travel per minute. It does not predict shaft or engine power, efficiency, an operating point, ventilation performance, structural loads or safety.

Steam-driven Ventilating Fan - Selected Air-Power/Conversion Ledger

Explore selected ideal air power, authoritative unit conversions and circular tip travel.

0°

Ideal Air Power
--
Converted Conventional Water-Column Pressure
--
Converted Volumetric Flow
--
Selected Geometric Tip Travel
--

Equation Used

P_air=Q Delta p/6356; Delta p_Pa=249.08891 Delta p_inH2O; Q_SI=0.0004719474 Q_cfm; v_tip=pi D N.
Selected ideal air-power, conversion and geometry arithmetic only; no shaft, engine, operating-point or safety prediction.
  • Flow, conventional water-column pressure, rotor diameter and rotational speed are entered values.
  • Q times pressure divided by 6356 is ideal air power, not shaft or engine power.
  • One cubic foot per minute is converted using 4.719474e-4 cubic metre per second.
  • One conventional inch of water is converted using 249.08891 pascals.
  • Tip travel is selected circumference times revolutions per minute; fan, drive, system and safety performance are excluded.

The secondary figure is an abstract arithmetic ledger, not a ventilating-fan or steam-engine design.

Same mechanism and inputs as the interactive calculator.

Selected air-power and conversion ledger

The Department of Energy fan-power relationship is evaluated with unit efficiency, so Q times pressure divided by 6356 is air power delivered to the airstream, not shaft power. NIST conversion factors convert the selected flow and conventional water-column pressure. Circumference pi D times selected revolutions per minute gives geometric tip travel per minute.

What the calculator determines

Use it to inspect the four stated arithmetic relationships for entered values. It cannot select, size or validate a fan, steam engine, drive, duct or mine-ventilation system.

Selected relationships

P_air=Q Delta p/6356; Delta p_Pa=249.08891 Delta p_inH2O; Q_SI=0.0004719474 Q_cfm; v_tip=pi D N.

Selected-input example

At 200000 cfm, 2 in conventional water column, 20 ft selected rotor diameter and 60 rpm, ideal air power is about 62.933 hp, converted pressure is about 498.178 Pa, converted flow is about 94.389 m3/s and selected geometric tip travel is about 3769.911 ft/min.

Not a fan or engine performance model

Fan efficiency, drive efficiency, shaft power, engine power, fan curve, system curve, density correction, compressibility, blade or diffuser geometry, actual rotor speed under load, stresses, guards, controls and ventilation safety are excluded.

Questions

Is air power the required shaft power?

No. The DOE equation divides by fan efficiency to obtain fan input power; setting efficiency to one leaves ideal power delivered to the air.

Does the selected flow occur at the selected pressure?

Not necessarily. An actual operating point requires validated fan and system curves.

Is tip travel a blade-stress limit?

No. It is only circumference times selected revolutions per minute.

Authoritative references

References & Further Reading

  • Wikipedia contributors. Mine ventilation. Wikipedia

Building or designing a mechanism like this?

Explore the precision-engineered motion control hardware used by mechanical engineers, makers, and product designers.

← Back to Mechanisms Index