An induction watt-hour meter integrates electrical energy by producing driving torque on a conducting disc from voltage- and current-coil fluxes. A separate permanent magnet produces braking torque that rises with disc speed. At ideal steady state, disc speed is proportional to real power, and a geared register counts disc revolutions as energy.
Recording Watt-hour Meter Interactive Calculator
Enter RMS voltage and current, power factor, run time and the meter constant Kh to calculate power, energy and ideal disc motion. The diagram shows how the coils drive the disc, the permanent magnet brakes it and the register counts rotation.
Equation Used
- Constant RMS voltage, RMS current and power factor for a single-phase sinusoidal load.
- Steady disc speed occurs where ideal drive and speed-dependent braking torques balance.
- Kh is the entered watt-hour constant per disc revolution.
- Friction, creep, waveform distortion, saturation, calibration adjustments and meter accuracy are excluded.
The second diagram follows the same inputs. Its small counter shows animation register-wheel turns; the result cards show energy and disc turns over the entered run time.
How the induction meter train works
The potential coil is connected across the supply, while the current coil is connected in series with the load. Their alternating magnetic fluxes induce currents in the conducting disc and produce a driving torque related to real power.
The disc also passes through the field of a separate permanent braking magnet. At ideal steady speed, the speed-dependent braking torque balances the driving torque. A rigid spindle and worm train transmit disc rotation to the register.
Playback speed is adjusted so the disc and gears remain visible. It does not reproduce mains frequency or the entered run time.
Calculating power and energy
Use the calculator to compare steady loads and the energy they use over time. Kh converts that energy into ideal disc revolutions. Choosing or calibrating a billing meter also requires its current and voltage ratings, accuracy specifications and the applicable utility requirements.
Do not open, adjust or work on an energized or sealed utility meter. Inspection, testing and service belong to the utility or another qualified authorized professional using the specific meter documentation.
Ideal single-phase relationships
For a steady single-phase sinusoidal load, using RMS voltage and current, real power is P = V I PF. Energy over t hours is E = Pt/1000 kilowatt-hours. If Kh is watt-hours per disc revolution, accumulated turns are N = Pt/Kh and ideal steady speed is n = P/(60Kh) revolutions per minute.
These equations neglect starting friction, creep, waveform distortion, temperature effects, bearing drag and calibration adjustments. They do not predict accuracy.
Example with the default inputs
At 240 V, 10 A and power factor 0.90, the real power is 2,160 W. Over one hour, the ideal energy is 2.160 kWh. With Kh = 7.2 Wh/rev, that corresponds to 300 disc revolutions and an ideal steady speed of 5 rpm.
The result cards report energy and disc turns for the entered hour. The small animation counter counts the illustrated register wheel, which turns once for every 16 disc turns. It does not show the entered-time total.
What Kh tells you
Kh supplies the energy-per-revolution relationship, but it does not by itself establish meter accuracy, current rating or suitability. Those depend on the identified instrument and its approved documentation.
The calculator uses one voltage, one current and a scalar power factor. It does not synthesize nonsinusoidal waveforms, harmonics, polyphase connections, magnetic saturation or compensating adjustments.
Watt-hour meter questions
Why is the potential coil connected across the supply?
It responds to the applied voltage. Together with the series current coil, it produces the magnetic fields that drive the conducting disc.
Why is the current coil connected in series?
It carries the load current, allowing its magnetic field to respond to the current being measured.
What does Kh mean?
Kh is the meter constant in watt-hours per disc revolution. Dividing energy in watt-hours by Kh gives the ideal disc-turn count. A larger Kh gives fewer turns for the same energy.
Why does changing run time leave disc speed unchanged?
Speed depends on power and Kh. Run time changes accumulated energy and disc turns, not the power level. At zero run time the totals are zero, but the animation can still illustrate rotation under the selected load.
Does the animation counter show the calculated disc-turn total?
No. The small counter follows the illustrated register wheel. In this drawing, one wheel turn takes 16 disc turns. The result cards show energy and disc turns for the entered run time. Playback speed is adjusted for visibility and is limited at very low and high calculated speeds.
Can the calculator establish meter accuracy?
No. It gives ideal energy and speed relationships for a steady single-phase sinusoidal load. It does not model calibration error, starting friction, creep, temperature effects or magnetic saturation.
Technical references
- US5399966A, Induction watt-hour meter rotary disc mounting and bearing system — motor, conducting disc, magnetic brake and register.
- US3123770A, Electric induction watt-hour meter with separate voltage and current magnetic structures and current flux adjusting means — separate voltage and current magnetic structures acting on a disc armature.
- US4030031A, Magnetic damping system for induction watthour meters — damping magnet, register and energy represented by disc rotation.
- NIST Technical Note 1179 — calibration of watt-hour meters and constants in watt-hours per revolution.
- NIST Special Publication 1193 — Kh terminology.