Quimby Screw Pump: Declared Flow and Power Ledger

← Back to Engineering Library

This page now separates the documented Quimby twin-screw topology from user-declared operating-point arithmetic. The animation shows counter-rotating screws and inward qualitative flow to a central discharge, while the calculator no longer presents an entered efficiency as measured performance.

Declared Positive-Displacement Operating Point

Enter a declared displacement, speed, volumetric-efficiency factor and pressure rise. The worksheet applies exact unit identities but does not generate a pump curve, leakage law, pressure capability or selection result.

0°

Declared-adjusted flow
--
Ideal hydraulic power
--
Ideal displacement flow
--
Declared flow difference
--

Equation Used

Q_i=D N; Q_d=eta_v Q_i; DeltaQ=Q_i-Q_d; P_h=Q_d DeltaP/1714
These are arithmetic identities on four user declarations. Q_d is not a measured actual flow, DeltaQ is not a leakage prediction, and hydraulic power is fluid power rather than shaft or motor power.
  • D is a declared displacement in US gallons per revolution and N is declared revolutions per minute.
  • Eta_v is a user-entered dimensionless factor, not predicted from geometry, clearances, pressure, viscosity or speed.
  • DeltaP is a declared pressure rise in psi and the factor 1714 converts GPM times psi to hydraulic horsepower.
  • The animated screws counter-rotate qualitatively and show inward flow from both ends toward the middle discharge documented by Hiscox.
  • Rotor profiles, pitch, chamber volume, timing, clearances and casing dimensions are not reconstructed.
  • Pump curve, leakage, compression, torque, shaft power, mechanical efficiency, NPSH, viscosity, cavitation, heating, materials, ratings, selection, operation and safety are excluded.

Retains exact declared flow and hydraulic-power identities, replaces performance prediction language with an explicit ledger, and adds a connected source-grounded twin-screw flow animation.

Two intermeshing screws convey fluid inward to a middle discharge

Hiscox's Quimby plate labels suction at both ends and discharge at the middle of a close-fitted twin-screw casing. US Patent 6,375,443 describes Quimby-type paired screw rotors whose profiles and housing form working chambers.

The animation preserves that topology qualitatively; it does not reconstruct the historical rotor profile or chamber volumes.

Use this as a declared operating-point ledger

The worksheet converts a declared displacement and speed to ideal flow, applies a declared volumetric factor, and converts declared flow and pressure rise to ideal hydraulic power.

It cannot identify a suitable pump, establish pressure capability or predict an operating point.

Declared flow and fluid-power identities

Q_i=D N; Q_d=eta_v Q_i; DeltaQ=Q_i-Q_d
P_h=Q_d DeltaP/1714

Q_d is declared-adjusted flow, not measured actual flow. P_h excludes mechanical and drive losses.

A transparent declared example

For D=0.50 gal/rev, N=900 rpm, eta_v=90 percent and DeltaP=600 psi, ideal flow is 450.0 GPM, declared-adjusted flow is 405.0 GPM, the declared difference is 45.0 GPM and ideal hydraulic power is 141.8 hp.

A ledger is not a pump curve

Real performance depends on rotor profile, clearances, viscosity, pressure, speed, temperature, gas content and internal leakage. Shaft and motor power additionally require mechanical and drive efficiencies.

The former actual-flow, slip-prediction, pressure-capability, application, maintenance and troubleshooting claims are removed or explicitly bounded.

Quimby ledger questions

Is eta_v predicted?

No; it is declared.

Is DeltaQ calculated leakage?

No.

Is hydraulic power shaft power?

No.

Does the animation reproduce the Quimby rotor profile?

No.

Quimby topology and fluid-power references

Building or designing a mechanism like this?

Explore the precision-engineered motion control hardware used by mechanical engineers, makers, and product designers.

← Back to Mechanisms Index