An ejector condenser brings cooling-water jets into direct contact with steam and discharges the resulting mixture. This calculator compares assumed cooling-water flow and total nozzle area. Enter steam flow, water-to-steam ratio, jet velocity and tail height to compare nozzle area and discharge flow under an assumed complete-condensation condition.
Ejector Condenser Interactive Calculator
Compare cooling-water flow and total nozzle area. The animation shows a multi-jet condenser and submerged tail outlet; complete condensation is an assumption, not a predicted result.
Equation Used
- Complete condensation assumed for liquid discharge mass.
- Water density 62.4 lb/ft³.
- Entered velocity is actual water exit velocity.
- Three equal jets illustrate total area allocation.
- Tail-height comparison does not establish required height.
No thermal-duty or vacuum prediction. H−34 ft is a reference comparison only.
Water jets, steam contact and drainage
The cutaway uses a multi-jet arrangement with a top water header, a side steam connection and converging jets directed toward the lower outlet. The tail pipe drains to a hotwell with its outlet below the water surface. The generic drawing is informed by the Type 591 section in Schutte & Koerting Bulletin 5AA.
Three equal nozzles are drawn for clarity. Their combined area equals the calculated total nozzle area. Blue markers show cooling water; fading purple markers identify the assumed condensation region. Their speed and fading are illustrative, not a residence-time or heat-transfer solution.
A conditional flow-sizing comparison
The calculator is useful for comparing cooling-water mass flow, selected nozzle velocity and nozzle flow area for an entered steam load. It does not specify a complete condenser or certify a vacuum duty.
Direct contact mixes condensate with cooling water. The model therefore treats the discharge as a combined stream, unlike a surface condenser where the two fluids remain separated.
Mass balance and nozzle area
For steam load ms and assumed water-to-steam mass ratio R, water flow mw=Rms. Under complete condensation, liquid discharge is mw+ms. Both are in lb/h.
Using water density 62.4 lb/ft³, water volume flow Q=mw/(3600×62.4) in ft³/s. For entered actual nozzle-exit velocity v in ft/s, total nozzle area A=Q/v. Equivalent circular diameter is deq=12√(4A/π) inches.
For the three equal nozzles illustrated, each bore diameter is deq/√3. This is an area allocation, not a claim that any three-nozzle device will achieve the entered duty.
The height result compares the entered value with a 34 ft reference: H−34 ft. It is not a minimum-height pass/fail check. A static pressure balance would require the pressure difference divided by liquid specific weight, with further allowances for actual drainage conditions.
Default sizing example
At 1600 lb/h steam and a 30:1 water ratio, injection water is 48,000 lb/h. Complete condensation would produce 49,600 lb/h liquid discharge.
At 40 ft/s selected water velocity, total nozzle area is about 0.00534 ft², equivalent to a 0.99 in circular bore. Three equal illustrated bores are about 0.57 in each.
At 34 ft outlet-to-hotwell height, the reference difference is zero. That says only that the entered height equals the reference; it does not establish vacuum or adequate drainage.
Thermal and pressure conditions remain necessary
No cooling-water temperature, steam enthalpy, discharge temperature, absolute condenser pressure, atmospheric pressure, gas load or piping loss is entered. Accordingly, the model cannot establish whether condensation is complete, what vacuum is achieved, or what height is required.
The required water ratio, attainable vacuum and drain height depend on the actual thermal duty and installation pressures. The assumed ratio must be supported by an appropriate thermal calculation and operating data.
Ejector-condenser calculator questions
Why does tail height not change injection flow?
The selected steam load and water ratio set that flow. No coupled pressure-flow model is included.
Is the nozzle diameter for one of the three visible jets?
The main result is the equivalent diameter for their total area. The diagram also shows the smaller diameter for each of three equal jets.
Does the animation prove complete condensation?
No. It illustrates the flow arrangement. The mass-balance result explicitly assumes complete condensation.
Does a negative reference difference mean the condenser cannot work?
No. The actual drain-height requirement depends on operating pressure and other installation conditions absent from these inputs.
Construction and drain-height references
Schutte & Koerting, Bulletin 5AA, page 3, Type 591 section: top water inlet, side vapor inlet and converging jets. The drawing here is generic and not a manufacturer sizing drawing.
Schutte & Koerting: Barometric Leg Defined: tail height is related to condenser-to-atmosphere pressure difference and hotwell level.