Screw Efficiency and Required Torque Calculator

Screw Efficiency and Required Torque Calculator

Estimate required screw torque and mechanical power from axial force, screw lead, efficiency, and linear speed. The result is a preliminary engineering estimate, not a product rating or safety approval.

Calculate screw torque from force

Enter the measured or assumed inputs in one unit system. The calculator converts to SI internally, evaluates the stated model, and displays the result in the selected unit system.

N
Enter axial force for the modeled condition.
mm
Enter screw lead per revolution for the modeled condition.
1
Enter screw efficiency for the modeled condition.
mm_s
Enter linear speed for the modeled condition.
Required input torque estimate --
Load-side mechanical power --
Enter values inside the documented model domain.

Engineering visualizer

Screw Efficiency and Required Torque Calculator visualizer Schematic, not to scale. The drawing updates from the production calculation engine and labels the main outputs.

Schematic, not to scale. The drawing updates from the production calculation engine and labels the main outputs.

Calculator by FIRGELLI Automations.

Embed this calculator

The responsive iframe opens the calculator-only view without Shopify navigation or footer. FIRGELLI attribution, the visualizer, and calculation-error reporting remain available.

F = 2000 N, lead = 8 mm, η = 0.35, v = 15 mm/s. T = 7.28 N·m. P_load = 30 W. Load-side watts ignore motor and gearbox loss.

Related checks: lead-screw torque and force calculator, lead-screw critical axial load calculator, and actuator power-supply sizing calculator.

What This Calculator Calculates

What does screw efficiency and required torque mean? This quantity describes one specific part of the actuator design problem. It should be read as a model output, not as a complete product selection rule.

When Not To Use This Calculator

When should I not use the screw efficiency and required torque model? Do not use this model when the inputs are unknown, the mechanism is outside the stated boundary, or the decision depends on manufacturer ratings, fatigue, shock, compliance, or regulated safety approval.

Engineering model and calculation details

Estimate required screw torque and mechanical power from axial force, screw lead, efficiency, and linear speed.

The page separates the calculator result from product selection. It explains the inputs, limitations, interpretation, and next design checks so the result is not mistaken for a complete actuator rating.

Governing equations

Quantity Equation Model meaning
Required input torque estimate T = F lead/(2pi eta) Calculates required input torque estimate for the stated simplified model.
Load-side mechanical power P_load = F v Calculates load-side mechanical power for the stated simplified model.

Variables and canonical units

Symbol Variable SI unit Domain
axial_force Axial force N finite engineering value in the documented model domain
screw_lead Screw lead per revolution m finite engineering value in the documented model domain
screw_efficiency Screw efficiency 1 finite engineering value in the documented model domain
linear_speed Linear speed m_s finite engineering value in the documented model domain
required_torque Required input torque estimate N_m finite result from valid inputs
load_side_power Load-side mechanical power W finite result from valid inputs

Assumptions and boundary conditions

  • Inputs represent one consistent operating condition.
  • The model uses the simplified boundary stated on the page.
  • The model begins and ends at the user-defined actuator or mechanism boundary.

Limitations and omitted checks

  • The result depends on user-entered values and simplified boundary conditions.
  • The model does not replace FIRGELLI product data, installation review, endurance testing, or a qualified engineering review.
  • Shock, fatigue, misalignment, mounting strength, and controller behavior may govern before the calculated value.

Worked example

F = 2000 N, lead = 8 mm, η = 0.35, v = 15 mm/s. T = 7.28 N·m. P_load = 30 W. Load-side watts ignore motor and gearbox loss.

Related checks: lead-screw torque and force calculator, lead-screw critical axial load calculator, and actuator power-supply sizing calculator.

What this model evaluates

Mode or effect Status Disclosure
calculated quantity evaluated The named output is evaluated for the stated model.
manufacturer rating not evaluated The result is not a manufacturer product rating.
installation detail not evaluated Mounting, alignment, shock, fatigue, and environment require separate review.

Common mistakes

  • Treating a simplified estimate as a manufacturer rating.
  • Mixing units or entering values measured at a different operating point.
  • Ignoring mounting, alignment, shock, duty cycle, or controller limitations.
  • Failing to compare the result with the next logical FIRGELLI design check.

Engineering references

  1. National Institute of Standards and Technology. NIST Guide to the SI. National Institute of Standards and Technology, Accessed 2026. Supports: SI unit definitions and unit-consistent engineering calculation display.. Accessed 2026-07-28. Source.
  2. Barry N. Taylor and Chris E. Kuyatt. Guidelines for Evaluating and Expressing the Uncertainty of NIST Measurement Results. National Institute of Standards and Technology, NIST Technical Note 1297. Supports: Root-sum-square treatment of independent standard uncertainty components.. Accessed 2026-07-28. Source.

Author, validation, and review status

Author: Robbie Dickson

Author profile: Robbie Dickson prepares FIRGELLI actuator education and calculator content for product users and engineering teams.

Engineering model type: Lead screw axial force to torque and power estimate

Validation: The production JavaScript engine is compared with a separately written Python oracle across known-answer, SI/imperial-equivalent, boundary, invalid-input, and randomized cases.

Questions about this calculator or found an error? Message our engineering team.