If you put two actuators under a platform and just divide the load in half, odds are high you'll get it wrong. Unless the centre of gravity is dead-on between both actuators, the split won't be even. One actuator will almost always be loaded more than the other, sometimes by quite a bit. This calculator works out the exact force on each actuator, from one up to four, once you know the load position and actuator locations. Formulas and step-by-step examples show you exactly what numbers to use.

What Is Load Distribution in a Multi-Point Lift?

Load distribution means working out how each support (actuator) shares the weight when they’re not all the same distance from the load’s CG. The rule: the closer an actuator is to the CG, the more of the weight it takes.

How does load distribution actually work?

Picture a seesaw. If someone sits in the centre, both ends push down by the same amount. Move the weight closer to one end and that end sees more force. Actuators under a platform act the same way. The one closest to the load’s CG gets the biggest share. The calculations are easy once you set the geometry.

A B W (Load) CG centred → equal forces CG − A B − CG A (58 lbs) B (42 lbs) CG CG off-centre → unequal forces Force A = W × (B − CG) / (B − A)   Force B = W − Force A
Motion design starts with geometry, not force alone.

With two actuators under a 100-lb load, don’t assume 50 lbs per side. The actual forces depend on where the actuators are placed and where the CG sits. Without that geometry, you’re guessing at best.

"The number one mistake we see on multi-point lifts is sizing every actuator for the average load. The average doesn't lift anything — the actuator closest to the centre of gravity does. Size each actuator for its actual calculated force, then add a safety factor." — Robbie Dickson, Founder and Chief Engineer of FIRGELLI Automations

Load Distribution (Multi-Point Lift) Calculator

The combined weight of everything being lifted
Distance from the left reference point to the load's CG
Position of actuator A along the beam
Position of actuator B along the beam
Position of actuator C along the beam
Position of actuator D along the beam
Engineering calculation notice

This calculator is intended for education, concept evaluation, and preliminary design. Results are based on the equations and assumptions described on this page, but cannot account for every real-world load case, tolerance, material property, environmental condition, installation detail, safety factor, code, or regulatory requirement. Verify all inputs, assumptions, units, and results independently before selecting components or using the result in a real application. Safety-critical, structural, medical, lifting, transportation, or regulated applications must be reviewed by a qualified engineer.

Found a calculation error? Message us

Load distribution interactive visualizer

Adjust the actuator and load positions and you’ll see in real time how the forces on each actuator shift. This helps you spot overloads before you build anything.

Number of Actuators
Total Load Weight 200 lbs
CG Position 24 in
Actuator A Position 0 in
Actuator B Position 48 in

ACTUATOR A FORCE

100 lbs

ACTUATOR B FORCE

100 lbs

FIRGELLI Automations — Interactive Engineering Calculators

🎥 Video — Load Distribution (Multi-Point Lift) Calculator

Load Distribution (Multi-Point Lift) Calculator

How do you use this calculator?

This tool works for 1 to 4 actuators under a single load. Here’s the process:

  1. Pick the actuator count — select from the dropdown. The page will display only the inputs needed for your configuration.
  2. Enter total load weight (in pounds). Add up everything the actuators must raise: the payload itself, the platform, hardware, and any accessories bolted on.
  3. Type in the centre of gravity position, always measured from the same left-side reference point. If unsure, hang the platform from two different points and mark where vertical lines cross — that’s your CG.
  4. Enter actuator positions, also from the same left reference point as above. It’s critical all positions use the same origin.
  5. Hit Calculate and read off the specific force each actuator will see. Always size by these numbers, not by the average.

What is the load distribution formula for multi-point lifts?

The main idea here is balance of moments and forces — sum of all actuator forces equals the load, and the moments about any point sum to zero. Depending on layout, here’s how the formulas break down:

1 Actuator:
Force A = W
2 Actuators:
Force A = W × (B − CG) / (B − A)
Force B = W − Force A
3 Actuators:
Sort actuators by position (left to right). The CG falls within one of two spans. Solve that span as a 2-actuator problem — the actuator bounding the other span carries zero load for that CG position.
4 Actuators (rectangular frame):
Treat as two independent 2-actuator pairs (A+C front, B+D rear). Split total load between pairs using the 2-actuator formula based on pair average positions, then split within each pair.
Symbol Variable Unit
W Total load weight lbs
CG Centre of gravity position from left end inches
A, B, C, D Actuator positions from left end inches
Force A, B, C, D Individual actuator load lbs

What does a 2-actuator load distribution calculation look like?

Scenario: You have a 100 lb solar panel array mounted on 2 linear actuators. Actuator A sits at the left end (0 inches) and Actuator B sits at 24 inches. Batteries bolted to the left side shift the centre of gravity to 14 inches from the left end.

Given: W = 100 lbs, CG = 14 inches, A = 0 inches, B = 24 inches

Calculate Force A:
Force A = 100 × (24 − 14) / (24 − 0)
Force A = 100 × 10 / 24
Force A = 41.67 lbs

Calculate Force B:
Force B = 100 − 41.67
Force B = 58.33 lbs

What this means: Actuator B — the one closer to the CG — carries nearly 40% more load than Actuator A. If you sized both actuators for 50 lbs thinking the load would split evenly, Actuator B would be operating dangerously close to its limit. You'd want to size both actuators for at least 58.33 lbs, ideally with a safety factor of 1.5 or more — so roughly 88 lbs capacity each.

How does this apply in real engineering work?

Why Equal Load Sharing Is the Exception, Not the Rule

Loads only split evenly if the CG is perfectly centred between actuators — which is rare. Hardware, mounting brackets, motors, and batteries rarely sit symmetrically. A few inches of CG shift can throw one actuator into overload while the other is lightly loaded or near idle. The side with the CG always takes most of the weight; that’s the one most likely to fail or wear out early.

Size Each Actuator for Its Actual Load

The biggest pitfall is dividing the total load evenly by actuator count and picking your actuator by that figure. That method misses the real load distribution. Always calculate the force for each position and add the appropriate safety factor. If one actuator sees 58 lbs in your worst case, pick a model rated for 87 lbs or more — don’t use a 50 lb actuator just because half the load "should" be 50 lbs.

Real-World Example — Solar Panel Arrays

For a 100 lb solar panel on 2 actuators, bolting a battery bank to one side moves the CG. Even if the panels are symmetric, the extra hardware upsets the balance. One actuator now supports 58 lbs, the other 42. That’s a 38% difference. Over time, this imbalance causes faster wear or outright failure on the heavy-loaded side, even though the total weight isn’t extreme.

4-Actuator Rectangular Frames

With 4 actuators at the corners of a rectangular frame, you break the problem into two 2-actuator calculations: one for the left/right split and one for the front/rear. Each pair then shares its assigned portion. With a rigid rectangular frame, this approach is accurate enough for most lifting applications and makes force calculations much easier.

Mechanical Compliance and Real-World Tolerance

No actuator setup is perfectly rigid; some compliance or flex is inevitable as things wear or heat up. Some think this "evens things out" enough to skip the math — but that just leads to binding, chattering, or uneven motion. Compliance is not a substitute for sizing actuators correctly. If your application requires all actuators to move in lockstep, use synchronization controls and stick with calculated force values for each actuator.

How do you calculate load distribution for a 4-actuator frame?

Scenario: You're designing a 4-actuator industrial lift platform for a 200 lb tool tray. The rectangular frame measures 48 inches long. Actuators A and C form the front pair (both at position 0 inches), while actuators B and D form the rear pair (both at position 48 inches). Heavy tooling mounted toward the rear shifts the CG to 22 inches from the left end.

Given: W = 200 lbs, CG = 22 inches, A = 0 in, C = 0 in, B = 48 in, D = 48 in

Step 1 — Find average pair positions:
Front pair (A+C) average position = (0 + 0) / 2 = 0 inches
Rear pair (B+D) average position = (48 + 48) / 2 = 48 inches

Step 2 — Split load between pairs:
Load on front pair = 200 × (48 − 22) / (48 − 0) = 200 × 26 / 48 = 108.33 lbs
Load on rear pair = 200 − 108.33 = 91.67 lbs

Step 3 — Split within each pair:
Since A and C are at the same position: Force A = 108.33 / 2 = 54.17 lbs, Force C = 54.17 lbs
Since B and D are at the same position: Force B = 91.67 / 2 = 45.83 lbs, Force D = 45.83 lbs

Design interpretation: The front pair carries about 18% more load than the rear pair because the CG is closer to the front (22 inches from front vs. 26 inches from rear). Every actuator should be rated for at least 54.17 × 1.5 = 81.3 lbs. We'd recommend our 100 lb rated actuators for this application — giving you comfortable headroom without oversizing.

What are common mistakes when using this calculator?

  1. Dividing total load by actuator count and using that as the size target. The article calls this "the number 1 mistake" — the actuator closest to the CG always carries more than the average.
  2. Measuring actuator positions and CG position from different reference points. All positions must originate from the same left reference point or the math returns nonsense.
  3. Forgetting to include mounting hardware, brackets, and payload accessories in the total load weight.
  4. Placing the CG outside the actuator span. If the CG sits beyond the outermost actuator, one actuator's calculated force becomes negative (it would need to pull down), which a typical extension actuator cannot do — the load will tip.
  5. Trusting mechanical compliance to "even out" an unbalanced design. Compliance can mask imbalance temporarily but introduces binding, uneven motion, and accelerated wear.
  6. Skipping the safety factor. The calculator returns ideal static forces — real systems see vibration, acceleration, and shock loading. Multiply by 1.5 minimum, 2.0+ for human-safety applications.

How can you verify the calculator output is reasonable?

  1. Force sum check. Add the individual actuator forces. The total must equal the input load weight (within rounding). If it doesn't, you entered a position or load incorrectly.
  2. Which actuator carries the most? The actuator closest to the CG should always show the highest force. If a far actuator shows more, you mixed up your position references.
  3. Symmetry check. Set the CG exactly halfway between two actuators and the forces should split equally. Move the CG and watch which side gets heavier — it should be the side you moved toward.
  4. Boundary check. Place the CG directly over one actuator's position. That actuator should read the full load, and the other should read zero. If not, your reference point is wrong.
  5. 3-actuator sanity. In 3-actuator mode, only the two actuators bracketing the CG carry load — the third reads zero. This is the conservative simplification; in a real flexible beam, the third actuator would carry some share, so size your two loaded actuators based on the calculator output and treat the third as backup capacity.

Frequently Asked Questions

What happens if my centre of gravity is outside the actuator positions? +

If the CG sits outside the span between your actuators, the math still works — but one actuator will calculate as a negative force, meaning it needs to push down (provide tension) instead of push up. In most linear actuator setups, this means your load will tip. Reposition your actuators so the CG falls between them, or add a third support point.

Can I use this calculator for metric units? +

Yes. The formulas are unit-agnostic for positions — enter millimetres or centimetres as long as you're consistent across all position fields. For load, enter in Newtons or kilograms-force instead of pounds. The ratios come out the same regardless of unit system. Just label your results accordingly.

How do I find the centre of gravity of my load? +

The simplest method: balance the loaded platform on a narrow edge (like a pipe) and find the point where it sits level. That's your CG along that axis. For more precision, place one end on a scale and the other on a fixed support — the scale reading and geometry give you the CG mathematically. For complex assemblies, CAD software calculates CG automatically from the 3D model.

What safety factor should I use when sizing actuators? +

We recommend a minimum safety factor of 1.5 for most applications — meaning you multiply your calculated worst-case actuator force by 1.5 and select an actuator rated at or above that number. For applications involving human safety (medical lifts, accessibility platforms), use 2.0 or higher. Dynamic loads that include vibration, shock, or acceleration also warrant a higher factor.

Does this calculator account for the weight of the actuators themselves? +

No — and for most setups, you don't need it to. Actuator self-weight is typically small compared to the payload. But if you're running near the capacity limit, add the weight of each actuator's moving components (rod and upper mounting) to your total load and recalculate the CG position accordingly. It's a small correction but worth doing in margin-critical designs.

Why does the 3-actuator mode only load 2 actuators at a time? +

Three collinear supports on a rigid beam create what engineers call a statically indeterminate system — there's no unique solution without knowing the beam's flexibility. Our calculator uses a practical simplification: it identifies which two actuators bracket the CG and solves that span. The third actuator carries zero in this model. In reality, beam deflection would distribute some load to the third actuator, but this approach gives you a conservative, safe-side estimate for the loaded actuators.

About the Author

Robbie Dickson — Chief Engineer & Founder, FIRGELLI Automations

Robbie Dickson brings over two decades of engineering expertise to FIRGELLI Automations. With a distinguished career at Rolls-Royce, BMW, and Ford, he has deep expertise in mechanical systems, actuator technology, and precision engineering.

Wikipedia · Full Bio

Need to implement these calculations?

Explore the precision-engineered motion control solutions used by top engineers.

Share This Article
Tags